1. Select this charge process by choosing LiPo CHARGE from the main menu by pressing the 

“Start/Enter” button.  The display should look similar to this:

LiPo CHARGE
2.0A  

11.1V(3S)

  When you want to change the values of parameters, please press “Start/Enter” key to make 

it blink and then use DES or”INC” to change the value. Then press “Start/Enter” key again to 
store the value.

2. The left side of the fi rst line shows the type of battery you choose. The value on the left of 

the second line of the charger is current user set, After setting the current and voltage, press 
“Start/Enter” key for more than 3 seconds to start the process (charge current: 0.1-5.0A, volt-
age: 1-5V). 

3. This displays the number of cells you set up and the processor detects. 

S:3SER    R:3SER
CONFIRM (ENTER)

 

Top Line:   S = Number of cells selected by you in the previous screen.

 

 

R = Number of cells detected by the charger.

  If both numbers are identical you can start charging by press “Start/Enter” button. If not, press 

“Batt type/Stop” button to go back to previous screen to carefully check the number of cells of 
the battery pack before going ahead.

4. This screen shows the real-time status during charge process. Press “Batt type/Stop” key 

once to stop the charge process.

Li3s   

  1.2A       12.59V 

BAL  

  022:43     00682

Number of cells

Battery voltage

Charging  time

Charged capacity

Charging current

Charging lithium battery in the balance mode

•  This function is for balancing the voltage of Lithium-polymer battery cells while charging. In the 

balance mode, the battery needs to have a balance lead to connect to the individual port at 
the right side of the charger. And you need to connect the battery’s output plug to the output 
of charger.

Charging in this mode is different from the normal modes, because the built-in processor moni-
tors voltage of individual cell and control input current fed into each cell to normalize the voltage.

1. Select this charge process by choosing LiPo BALANCE from the main menu by pressing the 

“Start/Enter” button.  The display should look similar to this:

Содержание I-Peak 665

Страница 1: ...Ref Y 023 I Peak 665 Professional Intelligent Digital Balance charger Instruction Manual...

Страница 2: ...f this product or for any loss or damage arising from omissions or inaccuracies in the associated instructions or materials included with this product We reserve the right to modify the design of this...

Страница 3: ...nt 1C 2C depends on the performance of cell Discharge voltage cut off level 0 85V cell NiCd 1 0V cell NiMH Li ion Voltage level 3 6V cell Max charge voltage 4 1V cell Allowable fast charge current 1C...

Страница 4: ...t the circuit automatically and alarm once detecting any malfunction All the programs of this product were controlled through two way linkage and communication to achieve the maximum safety and minimi...

Страница 5: ...e keeps being monitored If it drops below the lower limit the process will be ended automatically Data store load The maximum five batteries data can be stored for users convenience You can keep the d...

Страница 6: ...om mended charging current and charging time Especially the Lithium battery should be charged according the charging instruction provided by the manufacturer strictly Attention should be paid to the c...

Страница 7: ...cell count incorrectly at the beginning of charge or discharge process Otherwise default value is recommended to use Delta Peak Sensitivity The NIMH Sensitivity D Peak shows the trigger voltage for au...

Страница 8: ...d on or off Input Power This function monitors the voltage of the input battery used to power this charger If the voltage is lower than user set value the program will end forcibly to protect the inpu...

Страница 9: ...ead directly into this chargers balance ports If you are not sure what type of lead you have then check with your local model shop before connecting to the balance ports on this charger The main batte...

Страница 10: ...you can start charging by press Start Enter button If not press Batt type Stop button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead 4 Thi...

Страница 11: ...atus during charge process Press Batt type Stop key once to stop the charge process Li3s 2 0A 12 59V BAL 022 43 00682 Number of cells Battery voltage Charging time Supplied capacity Charging current F...

Страница 12: ...you can set up the current and voltage of the battery pack Charging and dis charging will make the batteries come to the voltage level of storage state LiPo STORAGE 2 0A 11 1V 3S This screen shows the...

Страница 13: ...c acid battery program This program is only suitable for charging Pb lead acid battery with nominal voltage from 2 to 20V Pb lead acid battery is completely different from NiCd NiMH battery These batt...

Страница 14: ...Start Enter key again to store the parameter value you set Press Batt type Stop key to end the program Pb 6 0 4A 12 59V DSC 022 43 00682 Battery type Battery voltage Elapsed time Discharged capacity...

Страница 15: ...t the program NIMH DISCHARGE 1 0A 11 5V The screen indicates the discharging state You can press Start Enter key to alter discharge current Press Start Enter again to store the value Press Batt type S...

Страница 16: ...meter Setting of the parameter in this screen will not affect the charge and discharge process They just represent the specification of the battery The following screens will automatically be displaye...

Страница 17: ...tor voltage of each cell while the battery is connected with each port of the charger End Voltage 12 06V 3s The final voltage when the program ended Capacity Cut Off ON 5000mAh Safety Timer ON 200min...

Страница 18: ...d CYCLE DCHG CHG 5 Start Dec Inc NiCd CYCLE DCHG CHG 3 2sec Start DCHG 1 0005mAh CHG 1 0000mAh Batt Dec Type PROGRAM SELECT LiPo BATT LiPo CHARGE 5 0A 22 2V 6S Start Dec Inc Start LiPo BALANCE 5 0A 22...

Страница 19: ...b 4 1 3A 9 80V DSC 000 31 00004 Pb CHARGE 0 6A 8 0V 4P Start Dec Inc Pb CHARGE 0 6A 6 0V 3P Batt Dec Type PROGRAM SELECT SAVE DATA Start SAVE 05 NiCH 7 4A 5000mAh Start 2sec Start 2sec Start Dec Inc S...

Страница 20: ...Wrong connection of the connector detected please check the connec tor and cable The charger has malfunctioned for some reason Seek professional advice The processor detects that the battery has dropp...

Отзывы: