7
SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic
system as a result of product shipment and handling. This step is to be completed without any weight on the
jack.
2. Turn release valve counter-clockwise on full turn
to the open position.
4. With a flat blade screwdriver, unscrew the oil fill
plug slightly to purge trapped air from system. (For
RUBBER OIL PLUGS Use caution not to tear or
puncture the oil plug.)
3. Rapidly pump the handle 6-8 times. Leave handle
in down position to expose oil fill plug.
6. Turn release valve clockwise to the closed
position.
7. Jack is now ready for use. Check for proper pump
action. (Repeat steps if neccessary).
Cover plate
Cover plate
1. Remove cover plate.
5. Replace Cover Plate.
Содержание BJ-830008
Страница 13: ...13 ASSEMBLY DIAGRAM ...