background image

 

 

 

  

Pump  

Motor 

Unusually 
noisy 

Pump 

High          
temp 

Condition 

Pump Area 

Possible Problem 

Solution 

 

 

Worn motor 

Replace motor 

Loose motor bolts 

Tighten bolts 

Coupling drive 

Adjust/replace coupling 

No end play on shaft 

Adjust coupling 

 

Dirt, low, improper oil 

Flush and replace oil 

Air leaks: 

 

1) caps/connection 

Tighten 

2) 

Gaskets/”O”-rings 

Replace/put on oil 

3) Fittings 

Replace/reseal 

Damaged or worn bearing 

Call factory 

Damaged or worn stators 

Call factory 

Pump out of adjustment 

Call factory 

 

Low voltage 

Short extension cord 

 

Dirty oil 

Flush and replace 

Low oil 

Add/replace 

Lint/foreign material 

Open gas ballast 

Parts friction 

Replace oil/call factory 

Too small for system 

Size pump for system 

Air leaks 

Replace/repair 

 

Motor  

Replacement Parts 

7, 8, 9, 16, 17, 18 

11 or 12,  
13, 14 and 15 

19 

6, 10 

Models #93530 and 93533 - 8 CFM (190 L/M) 

 

 

Diagnostics Chart 

Poor  
vacuum 

Quiet pump 

Exhaust 

Seal 

Case 

Oil 
Leaks 

Ultimate    
vacuum of 
pump - does   
not meet  
mfg. spec            
(read with           
thermocouple) 

Pump 
won’t  
start 

Motor 
stalled 
hot/cold 

Thermal 

Condition 

Pump Area 

Possible Problem 

Solution 

 

 

Dirty oil 

Flush 1 to 3 times 

Coupling or set screw loose  

Repair or replace

 

Bad exhaust valve  

Repair or replace

 

Pump not oiling  

Call factory   

Vanes not functioning  

Call factory   

Stator misaligned  

Call factory   

Worn pump bearings 

Call factory   

 

Pump dropped  

Call factory  

Bad thermocouple  

Clean or replace  

Bad motor  

Repair or replace  

Dirty oil  

Flush 1 to 3 times  

Air leaks  

Repair or replace  

System leaks  

Isolate/repair  

Fitting sealant compound 

Repair or replace 

 

System leaks 

Repair leaks 

Low oil level 

Add/replace 

Dirty oil 

Flush 1 to 3 times 

Worn pump 

Replace module, call factory 

Air leaks at fittings or gasket seals 

Replace/repair 

 

 

Oil level high  

Adjust oil level 

System vented pressure through pump   Check oil level, add or replace oil  

Pump tipped over 

Check oil level, add or replace oil 

 

Pump shaft  

Repair 

Worn or damaged seal  

Replace 

Motor loose 

Adjust/tighten, check seal 

 

Gasket bolts loose 

Tighten  

Oil drain fitting  

Repair or replace 

Gasket damaged 

Replace 

 

 

Damaged motor 

Repair or replace 

Damaged pump  

Replace/call factory 

 

Closed gas ballast on pumps 

Open intake fitting and gas ballast

 

 

Low voltage 

Shorter extension cord 

Cold weather cut-out 

Open intake fitting for 1 minute 
to warm up while starting

 

Dirty oil  

Flush 1 to 3 times  

Noisy 
pump 

Отзывы: