USER MANUAL 

TYPE ML-2012/13

    

Manufacturers of low power instruments 

 

page 5

 

1

 

Product Description 

 
The ML-2012/13 is designed to retrieve, and store data from various sensors. This data is logged onto the 
embedded SD-card. Also the stored data can be send from the data logger to any remote computer you 
like. To use this feature,  you need a valid SIM-card.  Contact  your local telecommunications supplier for 
more information on

 

the SIM card you will need. The unit accepts various power sources, selectable by 

the different version types. The user should connect his sensor(s) of preference to the connector board of 
the device. Captured data can be stored, send, visualized and manipulated in many ways. 
 
The ML-2012/13 data logger is a small, ultra low power, high-end data logger with built-in QUAD-band 
GPRS-modem. This small data logger, is further provided with an internal temperature sensor, 2 GB 
micro SD-card and an SIM card slot. The logger can be powered by an internal 3.6 Volt Lithium battery 
that will last for years when the logger is configured in a low-power mode. 
  
The ML-2012 data logger can acquire physical signals by 4 current loop inputs, 4 digital inputs The ML-
2013  data  logger  can  acquire  physical  signals  by  4  current  loop  inputs,  4  digital  inputs  and  2  hires 
amplified differential voltage inputs, which can be used to connect pyranometers or in combination with a 
stable excitation voltage to connect “Wheatstone resistive bridge sensors” like load cells.  
 
The  data  logger  is  provided  with  generic  serial  port  drivers  to  capture  measurements  from  ASCII, 
MODBUS/RTU,  NMEA  or  SDI-12  transponders,  custom  drivers  can  be  developed  on  request.  External 
sensors/transponders can be powered by the data logger itself, to prevent them to consume power while 
the data logger is a sleep. The excitation voltage is switched off during sleep as well. 
 
Its key features are; 
 

A maximum sample rate of 4 Hz, 

Recording length up to 2 GB,  

Four channel 12 bits A/D Convertor for accurate current loop measurements, 

Two channels 16 bits differential A/D convertor for low voltage measurements (

ML-2013 only

), 

Internal micro SD-card with standard FAT-32 File system for easy use with a PC, 

Various analogue and digital inputs for use with sensors (see specification sheet), 

Easy configuration by menu’s of embedded menu, 

Can be used with Windows XP, Vista and W7  

Low power / long Battery life (see specification sheet), 

Embedded GPRS/GSM modem for remote operation, 

Quad band modem for use all over the world, 

Alarming by SMS and data delivery by e-Mail, FTP or TCP 

Internal voltage convertor for supplying 12 VDC power to the connected sensor(s),  

Stable excitation voltage to power Wheatstone bridged sensors (

ML-2013 only

), 

Firmware upgrade over the air for adding new features to your device. 

Remote configuration over the air, for adjusting your configuration from remote. 

 
 
 

Содержание ML-2012/13

Страница 1: ...USER MANUAL TYPE ML 2012 13 Manufacturers of low power instruments page 1 Type ML 2012 13 Low power GPRS data logger Title User Manual ML 2012 13 Date 30 Oct 2014 Version 1 4...

Страница 2: ...12 13 data logger prepares you to install it and tells you how to put it into operation The Chapter Operating Basics covers basic principles of operation of the data logger The operating interface men...

Страница 3: ...4 6 Analog Differential Inputs ML 2013 only 20 4 6 1 Differential input ports theory of operation 20 4 6 2 Common mode noise rejection 20 4 6 3 Using Load Cells With the ML 2013 20 4 6 4 Bridge of Whe...

Страница 4: ...tion Battery Life 33 5 Pin configuration 34 5 1 ML 2012 34 5 2 ML 2013 35 5 3 Pin Description 36 5 3 1 Analog Inputs 36 Analog Input 1 to 4 36 Analog Input 5 to 8 ML 2013 only 36 5 3 2 RS 485 A B 36 5...

Страница 5: ...be used to connect pyranometers or in combination with a stable excitation voltage to connect Wheatstone resistive bridge sensors like load cells The data logger is provided with generic serial port d...

Страница 6: ...the logger to an external VDC source ML 2013 AC As ML 2013 but with 85 265V AC adapter integrated in cover To connect the logger to an AC power grid ML 2012 13 PCB As ML 2012 13 but without enclosure...

Страница 7: ...de PA66 GF20 with in between a silicon gasket The ML 2013 can be used outdoors 1 Analog inputs 2 RS232 connector 3 Excitation DC DC convertor 4 Digital inputs 5 SDI 12 power switch and Excitation conn...

Страница 8: ...he menu the configuration and network settings must also mach to those supplied by the SIM card provider The pin code of the SIM card must be removed prior to insertion in the data logger To prevent p...

Страница 9: ...on both devices ESD discharges could cause invisible damage This endangers long term stability and proper operation 2 3 Power on for the First time In the factory the data logger is programmed with th...

Страница 10: ...of the firmware NOT the wiring For wiring information see the reference Example Let s Configure a ML 2012 13 for operation with the following Analog pressure transmitter 4 20mA CT2X conductivity tempe...

Страница 11: ...Next type 7 for Analog sensors Choose 1 for Port 1 mA and the next screen will appear General settings 0 Exit 1 System Name YDOC 2 Data logging interval Normal 00 01 00 Alarm Not Used 3 Direct Data ou...

Страница 12: ...urement at 1m water level and a measurement at 2m water level while the sensors range is 0 10m 6 If necessary option 9 can be used to perform an offset correction by measuring a single calibration poi...

Страница 13: ...e interval of digital sensors too short 1 second is possible but probably not sec Just to be sure we choose 10 sec Consult the manual of your digital sensor and check the response time The sample inte...

Страница 14: ...ddress So make sure this address is valid Now perform an Email test and check if it is working right It is strongly recommended to include some internal sensors in the configuration because of the mon...

Страница 15: ...V Ctrl D The result should be like this Internal sensors 0 Exit 1 Name Internal 2 Sample interval Normal 00 00 01 Alarm Not Used 3 Battery Capacity mAh 17000 4 Battery replaced Yes 5 Rest Capacity Res...

Страница 16: ...is in the active state When the data logger is in sleep mode the tasks triggered by the sample interval will NOT execute 4 1 2 Data logging interval This interval determines when a data value obtaine...

Страница 17: ...user can evaluate these values every 5 seconds 4 2 SDI 12 The ML 2012 13 is provided with an SDI 12 port This port is connected to port 2 and is shared with the normal RS232 operation This means that...

Страница 18: ...ast character it switches to RX mode immediately without the delay Therefore no replies are missing Your ML 2012 13 has a true SDI 12 port For more information on the SDI 12 protocol see www sdi 12 or...

Страница 19: ...as a master and retrieves the information from the slaves Only one slave can respond to the requests of the master at a time To set up your RS485 sensor for use with the ML 2012 13 make sure that the...

Страница 20: ...s are very sensitive and particularly suitable for measuring signals from load cells 4 6 1 Differential input ports theory of operation Differential inputs are very convenient for measuring differenti...

Страница 21: ...table reverence Voltage often called Excitation Voltage The ML2013 has an Excitation output for this purpose 4 6 5 Excitation Output The ML 2013 has an Excitation output for powering load cells or oth...

Страница 22: ...is adjusted For input 5 this is very accurate it will be 0 05 For an application that requires an even higher accuracy the user can and should do a user overall calibration 4 6 9 Overall Calibration...

Страница 23: ...r systems or NPN outputs 4 7 2 Pull down type The pull up type of input means that there is an internal resistor mounted between the input and the ground So when NO signal is connected the input will...

Страница 24: ...his alarm level is reached when the data logger encounters a value which is higher than the high high Limit this is the 2nd and most urgent state of alarming This type of alarming is used for very rar...

Страница 25: ...ort 4 10 1 When to use Firmware upgrades Normally a user never uses this feature as long as he is satisfied with the performance of the system In time however the need for additional features may aris...

Страница 26: ...f INW CT2X sensors This sensor measures temperature and conductivity So each sensor uses two parameters Also he likes to send the data via FTP and he enables the following internal sensors Rest Capaci...

Страница 27: ...card adaptor or can be downloaded from the card by using the menu option Data download We recommend not removing the SD card from the logger 4 11 1 Inserting an SD card At the factory the SD card is a...

Страница 28: ...So the D record consists of a D character followed by a timestamp and after that one or more series of parameter code and parameter name So the D record consists of these elements 1 D 2 Parameter Cod...

Страница 29: ...m Message A short and comprehensive message to explain the type of problem encountered Additional System Message Some more information on the exception Example S records 4 12 3 Data Modifiers Normally...

Страница 30: ...ming a lot of power so try to minimize this Consult the manual of the sensor for warm up times A warm up time of 5 minutes is possible and can be used in rare situations but the battery life will be s...

Страница 31: ...other measurement For safety reasons a user can include some internal measurements in the configuration to allow monitoring of the performance of the system Example configuration Rain Measurement Here...

Страница 32: ...Quantity Quantity is the difference between the actual counter value and the previous counter value So when your data log interval is set to 10 minutes this parameter shows you the amount of pulses p...

Страница 33: ...the data logger this power monitor keeps track of the power consumption of the device When the device is going into sleep mode a fixed value is used to calculate the power consumption Both are calcula...

Страница 34: ...ve terminal analog input 3 4 0 20mA input 4 Positive terminal analog input 4 5 8 GND Ground X4 1 SDI 12 0 5V Terminal to connect SDI 12 sensors 2 Switched power output 12V 100mA Terminal to supply pow...

Страница 35: ...input 6 0 80mV Positive terminal analog input 6 8 diff input 6 0 80mV Negative terminal analog input 6 X4 1 Switched module power output 5V Terminal to switch on external modules a o display 2 SDI 12...

Страница 36: ...5 3 3 Power Switch This is an output to drive one or more sensors It holds a level of 12 Volts and is capable of driving up to 200 mA 5 3 4 VBAT This is the main power supply input for the board The...

Страница 37: ...re the antenna is in vertical position as the GSM and GPRS radio signals are vertically polarize the antenna should be vertical positioned for maximum performance Do not place the antenna near metal s...

Страница 38: ...fe stability see spec sheet Also when operating in a harsh environment the need for a recalibration can be applicable YDOC can perform overall calibrations any time you like 6 3 XRAY In the uncommon e...

Страница 39: ...disposed Regulations for disposal of batteries may be different Remove the batteries and dispose them in accordance to the local regulations for batteries 9 Transport and Storage The following requir...

Страница 40: ...solution 12 bits Input type 0 20 mA Channel 1 to 4 Number of Differential Channels 2 ML 2013 only Resolution 16 bits Input type Voltage 0 2000 mV 8 different ranges Smallest detectable step 1 uV Memor...

Страница 41: ...USER MANUAL TYPE ML 2012 13 Manufacturers of low power instruments page 41 11 EU Declaration of Conformity 11 1 ML 2012...

Страница 42: ...USER MANUAL TYPE ML 2012 13 Manufacturers of low power instruments page 42 11 2 ML 2013...

Страница 43: ...RS232 485 SDI 12 Generic SDI 12 NMEA GGA Generic RS232 NMEA DBT Generic RS232 NMEA HDG Generic RS232 NMEA MWV Generic RS232 AWAC Current Nortek RS232 AWAC Wave Nortek RS232 Thalimedes OTT RS232 SDI12...

Страница 44: ...y wrong it must be adjusted If it is totally out of date it designates a RTC problem There should be NO errors on this startup If there are errors contact your local YDOC dealer A screen dump of the s...

Страница 45: ...end us an email with your comments Thank you for your assistance Manual Name ML 2012 13__________________________________________________________ Revision Number 1 0___________________________________...

Отзывы: