INSTALLATION AND ADJUSTMENT
§
3 Installation & Adjustment
§3.1 Parameters
Models
Parameters
YT-81352
YT-81353
Input power
Single phase
ˈ
220-240V±10%, 50/60Hz
Single phase
ˈ
220-240V
±
10%,100V~120V
±
10%, 50/60Hz
Rated input current
˄
A
˅
46.4A
43.3A/110V,46.4A/230V
Rated input power
˄
KW
˅
8.5
3.8/110V,8.5/230V
Power factor
0.8
Welding current range
˄
A
˅
20
̚
210A
20A
̚
130A/110V,20A~210A/230V
Max no-load voltage(V)
67
57V/110V,67V/230V
Efficiency
ı
80
ˁ
Duty cycle
˄
40
ćˈ
10 minutes
ˈ
refer to
§
3.2
˅
210A/30%
130A/30%,210A/30%
115A/100%
71A/100%,115A/100%
Protection class
IP21s
Insulation class
F
Dimensions of Machine
˄
L
×
W
×
H
˅
˄
mm
˅
320*145*275
320*145*275
Note:
1. The above parameters are subject to change with the improvement of machines.
§3.2 Duty cycle & Over heat
The letter “X” stands for duty cycle, which is defined as the proportion of the time
that a machine can work continuously within a
certain time (10 minutes). The rated duty cycle
means the proportion of the time that a machine can
work continuously within 10 minutes when it
outputs the rated welding current.
The relation between the duty cycle “X” and the
output welding current “I” is shown as the right
figure.
If the welder is over-heat, the IGBT over-heat
protection unit inside it will output an instruction to cut output welding current, and
brighten the over-heat pilot lamp on the front panel. At this time, the machine should
be relaxed to cool the fan. When operating the machine again, the welding output
current or the duty cycle should be reduced.
I
˄
A
˅
0
100
ˁ
115
210
X
30%
The relation between duty cycle and
welding current for YT-81352,YT-81353
supplied by 230V/50Hz
7
Содержание YT-81352
Страница 21: ...5 3 Electrical principle drawing YT 81352 19...