15
O R I G I N A L I N S T R U C T I O N S
GB
Product when stored should be kept indoors, protect it from dust, dirt and moisture. It is recommended to store the product in its
original packaging.
Store the product in its working position. Do not tilt, do not store products in layers. Do not put anything on the product.
Removal of failures
Find below the typical defects, their causes and possible solutions. In case of any doubts, stop using the product, disconnect it
from power supply and contact the authorized service center of the manufacturer.
Failure
Possible cause
Problem solution
Device does not start
Device was not switched on
Check if the device has been properly connected and switched on using
the switch
Plug or cable were damaged
Contact the authorised service
Power failure.
Check the power supply
Damage of internal wiring
Contact the authorised service
Device starts, but the temperature
is too low / too high
Too much ice on the evaporator
Defrost the device
Condenser is locked by dust
Contact the authorised service
Improperly closed door
Check if the door was closed and its seal is undamaged
Device placed too close to heat source or fl ow of
air around the condenser was disrupted
Change the location of device
Too high ambient temperature
Increase effi ciency of ventilation or displace the device to cooler location
Improper foodstuff s placed in refrigeration
chamber
Remove excessively warm food, check if the food does not block the fans
Device overloaded
Reduce quantity of foodstuff s inside the device.
Water leaks from the device
Device was not levelled
Level the device
Drainage outlet was blocked
Clean the outlet
Disrupted water outfl ow
Clean the fl oor of the device
Damaged water container
Contact the authorised service
Water container overfl own
Empty the water container
Device is excessively loud
Loosen screws or nuts
Check and tighten screws and nuts
Device has not been levelled or it stands
unstably
Check the position of the product and change it if necessary.
TECHNICAL DATA
Parameter
Measuring unit
Value
Catalogue number
YG-05250
YG-05251
YG-05255
YG-05256
YG-05260
YG-05262
YG-05270
Rated voltage
[V~]
220-240
220-240
220-240
220-240
220-240
220-240
220-240
Rated frequency
[Hz]
50
50
50
50
50
50
50
Rated current
[A]
2
4
2
4
1.2
1.2
1.2
Rated power
[W]
215
520
230
560
170
170
170
Insulation class
I
I
I
I
I
I
I
Climatic class
4
4
4
4
4
4
4
LED lamp power
[W]
-
-
-
-
-
-
-
Operating temperature
[
O
C]
-2/+8
-18/-22
-2/+8
-18/-22
+2 / +8
+2 / +8
+2 / +8
Rated capacity
[l]
282
282
417
417
240
240
240
Coolant (type / weight)
R290 70g
R290 95g
R290 70g
R290 95g
R600A 65g
R600A 65g
R600A 65g
Insulation foaming agent
C5H10
C5H10
C5H10
C5H10
C5H10
C5H10
C5H10
Net weight
[kg]
102
110
134
159
76
70
75
Noise level
- acoustic pressure LpA ± K
[dI(A)]
< 70
< 70
< 70
< 70
< 70
< 70
< 70
- power LwA ± K
[dI(A)]
< 80
< 80
< 80
< 80
< 80
< 80
< 80
Max. load on shelves / containers GN
[kg]
40
40
40
40
40
40
40
Parameter
Measuring unit
Value
Catalogue number
YG-05275
YG-05280
YG-05290
YG-05300
YG-05305
YG-05310
Rated voltage
[V~]
220-240
220-240
220-240
220-240
220-240
220-240
Rated frequency
[Hz]
50
50
50
50
50
50
Rated current
[A]
1.2
1.2
1.6
1.6
1.6/0.8
2
Содержание YG-05250
Страница 24: ...24 RUS 8 45 12 10 30...
Страница 26: ...26 RUS GN SET SET 5 SET 2 O C O F SET 10 SET 3 O C O F SET SET SET 15...
Страница 29: ...29 RUS YG 05350 YG 05355 YG 05356 YG 05360...
Страница 31: ...31 RUS LpA K A 70 70 70 70 70 70 LwA K A 80 80 80 80 80 80 GN 40 40 40 40 L E N L L N M M C R S...
Страница 91: ...I N S T R U K C J A O R Y G I N A L N A 91...
Страница 92: ...I N S T R U K C J A O R Y G I N A L N A 92...