4.2.10 ALARM 3002 (EMERGENCY STOP)
Table 4.12
Cause of Trouble
Emergency stop button
depressed, or, machine
end LS is out of place.
Failure of FC230B or
Drop of +24 V power
voltage
Check Method
ensuring
signal #3500
O
(during emergency stop), check
continuity of emergency stop button or
machine end LS shown below. For
connection, refer to connection
diagram prepared by machine
manufacturer.
FC230B
f
CN27-10,11
M A C H I N E
END LS
I
MACHINE END
RELEASE
This FC230 failure if alarm 3002 lights
even at #3500
= 1
Check +24 VDC power. If the voltage is
below +20 V, it indicates possible trouble.
Solution
Reset the emergency stop
button. Release it from
machine end LS according
to instruction manual
prepared by machine tool
manufacturer.
Replace FC230B or
Contact your YASKAWA
representative.
Replace
or
(power supply
unit).
Contact your YASKAWA
representative.
93
Содержание YASNAC i80
Страница 3: ...YASNAC i80 CNC SYSTEM FOR MACHINE TOOLS MAINTENANCE MANUAL v YASUAW14 ...
Страница 26: ...1 2 COMPONENTS Cent d 16 14 ACGC Operation Panel Model JZNC IOP1l E u v d 1 2 0 a L ...
Страница 30: ... I A om o amvr _ fi___ n ___ __n__n WI c ___________ ...
Страница 31: ... M o d e l JAN CD FC190 1 Approx mass 0 32 kg M o d e l JAN CD FC200 Approx mass 0 3 kg be _____ _ _ _ __ a 21 ...
Страница 35: ... Model JAN CD FC31O 1 Spindle control 1 axis Approx mass 0 24 kg 4 q ___ _ _ __ R x a FC31 O L 25 ...
Страница 41: ... Model JANCD FC260 I Ha Approx mass 0 34 kg 1 ...
Страница 45: ... rl v JANCD Fc050 1 B r 1 2 q 11 ...
Страница 206: ...196 ...
Страница 225: ... e Enter the desired pitch error number R f Depress the WRQ key The pitch error number is entered 215 I ...