Chapter 4 Serial communication
Manual VIPA System 200V
4-12
HB97E - CPU - RE_21x-2BS03 - Rev. 15/16
You may transfer parameters to the CP via SEND (SFC 230), ANR=201
and DB.
Please regard that a send command is only executed when the following
conditions are met:
•
the SEND has received a RLO "1"
•
the Bit "order in process" in the indicator word has been reset
Name
Declaration
Type
Description
SSNR IN
INT
Interface
number
ANR
IN
INT
Job number
IND
IN
INT
Mode of addressing
QANF
IN
ANY
Pointer to data source
PAFE OUT BYTE
Parameterization
error
ANZW IN_OUT
DWORD Indicator
word
A RESET with order number 0 interrupts all orders and the previous
parameters are activated.
Analog to SEND, the block requires a preceding RLO=1.
Name
Declaration
Type
Description
SSNR IN
INT
Interface
number
ANR
IN
INT
Job number
PAFE OUT BYTE
Parameterization
error
CALL SFC 235
SYNCHRON
SSNR:=0
BLGR:=6
PAFE:=MB199
SET
RLO=1
CALL SFC 230
SEND: parameter for COM1
SSNR:=0
ANR :=201
ID for parameterization
IND :=0
QANF:=P#DB9.DBX0.0 BYTE 20
Pointer to parameter for COM1
PAFE:=MB198
ANZW:=MD200
SET
RLO=1
CALL SFC 230
SEND: parameter for COM2
SSNR:=0
ANR :=201
ID for parameterization
IND :=0
QANF:=P#DB9.DBX20.0 BYTE 20 Pointer to parameter for COM2
PAFE:=MB198
ANZW:=MD200
SET
RLO=1
CALL SFC 234
RESET
SSNR:=0
ANR :=0
ID for RESET
PAFE:=MB197
SFC 230 - SEND
with ANR=201
and Parameter-DB
Parameters
SFC 234 - RESET
Parameters
Example OB100
Содержание VIPA System 200V
Страница 1: ...VIPA System 200V CPU Manual HB97E_CPU RE_21x 2BS03 Rev 15 16 April 2015 ...
Страница 4: ...Contents Manual VIPA System 200V ii HB97E CPU RE_21x 2BS03 Rev 15 16 ...
Страница 8: ...Safety information Manual VIPA System 200V 4 HB97E CPU RE_21x 2BS03 Rev 15 16 ...
Страница 66: ...Chapter 3 Deployment CPU 21x 2BS03 Manual VIPA System 200V 3 28 HB97E CPU RE_21x 2BS03 Rev 15 16 ...