Options
6-
163
Setting Output Items for the DO-02C Digital Output Board
If using DO-02C Digital Output Board, set the output items using F5-01 and F5-02.
Setting Output Items for the DO-08 Digital Output Board
If using DO-08 Digital Output Board, select one of the following three output modes according to the setting
in F5-09.
F5-09 Set to 0
F5-07
Channel 7 out-
put selection
Effective when a DO-08 Digital
Output Board is used.
Set the number of the multi-func-
tion output to be output.
0 to 37
0F
No
A
A
A
A
A
39FH
DO Ch7 Select
F5-08
Channel 8 out-
put selection
Effective when a DO-08 Digital
Output Board is used.
Set the number of the multi-func-
tion output to be output.
0 to 37
0F
No
A
A
A
A
A
3A0H
DO Ch8 Select
F5-09
DO-08 output
mode selection
Effective when a DO-08 Digital
Output Board is used.
Set the output mode.
0: 8-channel individual outputs
1: Binary code output
2: Output according to
F5-01 to F5-08 settings.
0 to 2
0
No
A
A
A
A
A
3A1H
DO-08 Selec-
tion
Set Value
Terminal
Number
Output Details
0: 8 separate
outputs
TD5-TD11
Overcurrent (SC, OC, GF)
TD6-TD11
Overvoltage (OV)
TD7-TD11
Inverter overload (OL2)
TD8-TD11
Fuse blown (PUF)
TD9-TD11
Overspeed (OS)
TD10-TD11
Inverter overheated (OH1) or motor overload (OL1)
TD1-TD2
Zero-speed detected
TD3-TD4
Speed agreement
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2