www.dadehpardazan.ir 88594014-15
3 Wiring and Connection
3.2.1 Connecting to SGDV-
05
SERVOPACK (Analog Pulse Model)
3-6
Using a Single-phase, 200-V Power Supply
The
-V Series SERVOPACK for a 200-V power supply input has input specifica-
tions for a three-phase power supply, but some models can also be used with a single-
phase 200-V power supply. For details, refer to
-V Series User's Manual Design and
Maintenance Linear Motor/Analog Voltage and Pulse Train Reference
(SIEP
S800000 47).
Before connecting an external regenerative resistor to the SERVOPACK, refer to
necting Regenerative Resistors
R S T
SGDV-
A05
SERVOPACK
Power supply
Single-phase 200 VAC
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power supply
line by shutting the
circuit OFF when
overcurrent is
detected.
Used to eliminate
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor
*
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory) inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
I/O signal cable
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
Host controller
Linear servomotor
main circuit cable
Serial converter unit
Cable for connecting a
serial converter unit
Linear servomotor
with core
Linear scale
(Not included)
Cable for connecting a
hall sensor
Cable for connecting a
linear scale