www.dadehpardazan.ir 88594014-15
5 Trial Operation (Checking Linear Servomotor Operation)
5.5.2 When Using an Absolute Linear Scale
5-20
Using the Panel Operator
Step
Display after operation
Keys
Operation
1
Press the MODE/SET Key to select the Utility
Function mode.
2
Press the UP or DOWN Key to select Fn080.
3
Press the DATA/SHIFT Key for
approximately one second. The display shown
on the left will appear.
4
Press the MODE/SET Key to start the polarity
detection.
5
When the polarity detection is complete, the
display shown on the left will appear.
The linear servomotor will be in servo OFF
status.
6
Press the DATA/SHIFT for approximately one
second. The display will return to Fn080.
7
Turn OFF the power to the SERVOPACk and then ON again to enable the setting.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
Содержание SGLC
Страница 57: ...www dadehpardazan ir 88594014 15 2 Installation 2 4 1 Orientation 2 34 Duct ventilated Air Flow Duct...
Страница 85: ...www dadehpardazan ir 88594014 15 2 Installation 2 5 5 Other Precautions 2 62...