1 Outline
1.5.2 Basic Specifications
1-8
I/O
Signals
Encoder Output Pulse
Phase A, B, C: line driver
Encoder output pulse: any setting ratio (Refer to
4.2.6
.)
Sequence
Input
Input
Signals
which can
be allocated
Number of
Channels
7 ch
Functions
• Forward run prohibited (P-OT), reverse run prohibited
(N-OT)
• Forward external torque limit (/P-CL), reverse external
torque limit (/N-CL)
• DB answer (/DBANS)
• General-purpose signals (/SI0 to /SI6)
*2
Signal allocations can be performed, and positive and
negative logic can be changed.
Sequence
Output
Fixed Output
Servo alarm (ALM) output
Output
Signals
which can
be allocated
Number of
Channels
3 ch
Functions
• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Rotation detection (/TGON)
• Servo ready (/S-RDY)
• Torque limit detection (/CLT)
• Speed limit detection (/VLT)
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)
Signal allocations can be performed, and positive and
negative logic can be changed.
Communi-
cations
Function
RS422A
Commu-
nications
(CN3)
Interface
Digital operator (Model: JUSP-OP05A-1-E), personal computer (can be con-
nected with S)
1:N
Communica-
tions
N = Up to 15 stations possible at RS422A
Axis
Address
Setting
Set by parameter
USB
Commu-
nications
(CN7)
Interface
Personal computer (can be connected with S)
Communica-
tions
Standard
Complies with standard USB1.1. (12 Mbps)
LED Display
CHARGE, and POWER indicators, one 7-segment LED
Option Module Setting Switches
Rotary Switch
(S2)
Position: 16 positions (Refer to )
DIP Switch (S3)
Number of pins: Four pins (Refer to )
Analog Monitor (CN5)
Number of points: 2
Output voltage:
±
10VDC (linearity effective range
±
8 V)
Resolution: 16 bits
Accuracy:
±
20 mV (Typ)
Max. output current:
±
10 mA
Settling time (
±
1%): 1.2 ms (Typ)
Dynamic Brake (DB)
*3
Included
An external dynamic brake unit is required.
*4
Regenerative Processing
Included
An external regenerative resistor unit is required.
*5
Overtravel Prevention (OT)
Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or
N-OT
Protective Function
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.
Utility Function
Gain adjustment, alarm history, JOG operation, origin search, and so on.
(cont’d)