900-200-100 53/57
12.3.2.
∑-7W
Parameter
No.
SIZE
Name
Setting Range
Units
Factory
Setting
When Enabled
Pn518
2
Output Signal
Selection 7
-
-
0000
After resetting the
system or
recalculating
parameters
Active Mode ON Signal Mapping
Digit
0
0
Disabled (the above signal output is not used).
1
Axis A: Output the signal from the CN1-1 and CN1-2 output terminals.
Axis B: Output the signal from the CN1-23 and CN1-24 output terminals.
2
Axis A: Output the signal from the CN1-25 and CN1-26 output terminals.
Axis B: Output the signal from the CN1-27 and CN1-28 output terminals.
3~6
Reserved settings (Do not use.)
1
Refer to the SERVOPACK manuals.
2
3
Pn5BF
2
/ACT_MOD (Active
Mode On ) Signal
Allocation
-
-
0000
After resetting the
system or
recalculating
parameters
Allocated Pin Number
Digit
0
~
2
000
Disabled (the above signal output is not used).
001
Allocate the signal to CN1-1 and CN1-2.
023
Allocate the signal to CN1-23 and CN1-24.
025
Allocate the signal to CN1-25 and CN1-26.
027
Allocate the signal to CN1-27 and CN1-28.
029
Allocate the signal to CN1-29 and CN1-30.
Polarity Selection
Digit
3
0
Disabled (the above signal output is not used).
1
Output the above signal.
2
Invert the above signal and output it.