E-28
8 MEASURES TO SATISFY THE EMC DIRECTIVE
This section describes the measures required for the NS300 Module to conform to EMC Direc-
tive (EN50081-2, EN50082-2).
8.1 DeviceNet Communication Cable
For DeviceNet (CN6 connector), use the cable for special use.
For max. cable length, refer to “4.4 Precautions for Wiring DeviceNet Cables”
Use the special DeviceNet cable.
8.2 Fully Closed Encoder Cable
For fully closed encoder (CN4) connector, use the following connector.
Use the twisted pair shielded cable.
Connector: 54306-2011 (Made by Molex Japan Co., Ltd.)
Connector case: 54331-0201 (Made by Molex Japan Co., Ltd.)
8.3 The Core on the Cable
Attach the core on the cable as shown below:
Cable line and the line position where the core are attached are shown below.
Note: For details on the SERVOPACK core and the line filter, refer to
Σ−ΙΙ
series SGDH Instruction Manual (TOB-S800-32).
Model
ESD-SR-25
ESD-SR-250
(RoHS compliance)
Quantity
1
Turn
2
Manufacturer
Tokin.Corp.
Cable Name
Mounting Position of Core
DeviceNet Communication Cable
Near the host controller and SERVOPACK
Fully Closed Encoder Cable
Near the SERVOPACK
Cable
Core