E-5

„

INSTALLATION

„

WIRING

„

OPERATION

(Ref.No.)

•  Never use the equipment where it may be exposed to splashes of water,  corrosive 

or flammable gases, or near flammable materials.

Failure to observe this caution may lead to electric shock or fire.

E-13

CAUTION

(Ref.No.)

•  SERVOPACK grounding must be in accordance with the national code and consis-

tent with sound local practices.

Failure to observe this warning may lead to electric shock or fire.

E-16

(Ref.No.)

•  Do not connect three

-

phase power supply to SERVOPACK output terminals U, V, 

and W.

Failure to observe this caution may lead to personal injury or fire.

E-16

•  Securely tighten screws on the power supply and motor output terminals.

Failure to observe this caution may result in a fire.

E-16

WARNING

CAUTION

(Ref.No.)

•  To avoid inadvertent accidents, run the servomotor only in test run (without load).

Failure to observe this caution may result in personal injury.

E-25

•  Before starting operation with a load connected, set up parameters suitable for the 

machine.

Starting operation without setting up parameters may lead to overrun failure.

E-25

•  Before starting operation with a connected load, make sure emergency

-

stop proce-

dures are in place.

Failure to observe this caution may result in personal injury.

E-25

•  During operation, do not touch the SERVOPACK

s heatsink.

Failure to observe this caution may result in burns.

E-26

CAUTION

Содержание S-II Series

Страница 1: ...II AC Type JUSP NS300 JUSP NS300 E DeviceNet Application Module II Series AC Servo Drives INSTRUCTIONS To properly use the product read this manual thoroughly and retain for easy reference inspection...

Страница 2: ...liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quality products the information contained in this...

Страница 3: ...nglish Version Described on pages E 1 to E 30 Use the Japanese Version or English Version as needed User Instructions Use these instructions for the following jobs Checking II Series SERVOPACK on deli...

Страница 4: ...2 3 Type Designation E 10 2 4 Mounting NS300 Module E 10 3 INSTALLATION E 13 3 1 Storage E 13 3 2 Installation Sites E 13 3 3 Orientation E 14 3 4 Installation Precautions E 14 4 WIRING E 16 4 1 Devi...

Страница 5: ...s at Operation E 26 7 INSPECTION AND MAINTENANCE E 27 8 MEASURES TO SATISFY THE EMC DIRECTIVE E 28 8 1 DeviceNet Communication Cable E 28 8 2 Fully Closed Encoder Cable E 28 8 3 The Core on the Cable...

Страница 6: ...e read this manual thoroughly and retain for easy refer ence for inspections and maintenance etc DeviceNet is a trademark of ODVA Open DeviceNet Vender Associa tion Inc Reference materials are listed...

Страница 7: ...00 Module mounted the parame ters are automatically set so that the NS300 Module can be operated from the first power ON For details of parameter setting methods refer to II Series SGM SGDH User s Man...

Страница 8: ...njury or fire E 16 Securely tighten screws on the power supply and motor output terminals Failure to observe this caution may result in a fire E 16 WARNING CAUTION Ref No To avoid inadvertent accident...

Страница 9: ...cation Some drawings in this manual are shown with the protective cover or shields removed in order to describe the detail with more clarity Make sure all covers and shields are replaced before operat...

Страница 10: ...all power and wait 5 min before servicing May causeelectric shock Do not touch heat sink when power is ON Use proper grounding techniques 5 WARNING CAUTION SERVOPACK warning label position SERVOPACK...

Страница 11: ...ess Rotary switches DR Used to set baud rate for DeviceNet RS 232C Communications Connector CN11 Used to communicate with the NSxxx Setup Tool LED MS Module Status LED LED NS Module Status LED DeviceN...

Страница 12: ...of parameter setting methods refer to II Series SGM SGDH User s Manual SIEPS80000005 CAUTION Check Items Remarks Check if the delivered products are the ones you ordered Check the types marked on the...

Страница 13: ...d screws with spring washer and plain washer Attachments SGDH 60 to 1EAE SGDH 60 to 1EDE M4 8 round head screws with spring washer and plain washer Use the screw of the front panel Rack mounted SGDH A...

Страница 14: ...n module to the marked G on the SERVOPACK CN10 Connector to SERVOPACK YASKAWA SERVOPACK SGDH Ver L1 L2 1 2 POWER CHARGE L1C L2C B1 B2 U V W G Ground wire For SERVOPACK 30 W to 5 0 kW MODE SET DATA CHA...

Страница 15: ...E 12 The appearance of SERVOPACK with application module properly mounted is shown below...

Страница 16: ...en installed in a control panel Design the control panel size unit layout and cooling method so that the temperature around the periphery of the SERVO PACK does not exceed 55 C When installed near a h...

Страница 17: ...alling multiple SERVOPACKs side by side in a control panel observe the follow ing installation method Front Panel Install SERVOPACK perpendicular to the wall so that the front panel digital operator m...

Страница 18: ...PACKs to prevent the temperature around each SER VOPACK from increasing excessively and also to maintain the temperature inside the con trol panel evenly Environments in Control Panel Maintain the fol...

Страница 19: ...rcuit wiring I O signal wiring Encoder wiring Example of connections SERVOPACK grounding must be in accordance with the national code and consistent with sound local practices Failure to observe this...

Страница 20: ...oller and a NS300 Module CN6 using DeviceNet communications cables DeviceNet Master Module PLC or personal computer SERVOPACK SERVOPACK Inverter 63 nodes max Machine I O signals Manufactured by OMRON...

Страница 21: ...h the multi drop method Both T branch and multi drop methods can be used together in the same network as shown in the figure above Terminator Both ends of the trunk line must connect to terminating re...

Страница 22: ...ng to Three Drop Lines Direct Node Connection Trunk line Trunk line Drop line NS300 Module NS300 Module NS300 Module T Branch Adapter Trunk line Multi drop method Trunk line NS300 Module Drop line Dro...

Страница 23: ...ength is either the line length between two nodes located farthest from each other or the line length between the terminators on the ends of the trunk line whichever is longer Name Model Manufacturer...

Страница 24: ...k cable length LTHIN Thin cable length Drop Line Length The drop line length is the line length between a branch point on the trunk line to the farthest node that is located on the drop line The maxim...

Страница 25: ...ol lowing table The following example is for a baud rate of 500 Kbps The above example must satisfy the following conditions a 6 m b 6 m c 6 m d 6 m d f 6 m d e g 6 m d e h 6 m The total drop line len...

Страница 26: ...he allowable current I of the drop line i e the allowable current consumption of the drop line and devices connected to it from the following equation I 4 57 L I Allowable current A L Drop line length...

Страница 27: ...int If more than one communications power supply is connected to the network connect them using a Power Supply Tap each 1 Power supplies are not counted as nodes 2 Ground the network to a resistance o...

Страница 28: ...set to other than 0 the servo motor may oscillate To avoid this make sure to set the load inertia to 0 and then servo ON Conducting Test Run with Servomotor Connected to Machine SERVOPACK initial par...

Страница 29: ...items should be checked during test run Unusual vibration Abnormal noise Excessive temperature rise 6 2 Precautions at Operation During operation do not touch the SERVOPACK s heatsink Failure to obse...

Страница 30: ...m cannot be solved by the proce dures described Be sure to turn OFF power before inspection or maintenance Otherwise electric shock may result Never open the terminal cover while power is ON and never...

Страница 31: ...nector Use the twisted pair shielded cable Connector 54306 2011 Made by Molex Japan Co Ltd Connector case 54331 0201 Made by Molex Japan Co Ltd 8 3 The Core on the Cable Attach the core on the cable a...

Страница 32: ...Fix and ground the cable sheld using a piece of conductive metal Example of Cable Clamp SERVOPACK side Ground plate Cable Cable Clamp Shield cable sheath stripped Remove paint on mounting surface Fix...

Страница 33: ...ounding plate are securely connected to the grounding 3 Remove the paint from the grounding plate to insure a good Earth connection for filter SERVOPACK clamp etc REQUIRED EN SPECIFICATIONS Grounding...

Страница 34: ...ation Chapter 5 Addition Description of EDS file Back cover Revision Address December 2006 All chapters Revision Unit changed to module Interface unit changed to application module Chapter 2 Addition...

Страница 35: ...e Road HuangPu District Shanghai 200003 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 http www yaskawa com cn YASKAWA ELECTRIC CHINA CO LTD BEIJING OFFICE Room 1011 Tower W3 Oriental Plaza No 1 East...

Отзывы: