6.2.4 Replace the Inverter
Please confirm the following things before replacing the inverter:
(1) The inverter is turned off.
(2) The DC switch of the inverter is turned to OFF position.
Then Replace the inverter according to the following steps:
a.) Unlock the padlock if it is installed on the inverter.
Figure 6.2 - Unlock the Padlock
b.) Use a No.2 Phillips head screwdriver to unscrew the 2 screws on both sides of the
inverter.
Figure 6.3 - Remove the Screws on Both Sides
c.) Use a No. 10 Hex wrench to remove the 4 screws between the main section and
the wiring box. Lift up the main section and disconnect from the wiring box.