A-91
A
Appendices
( 7 ) Data Address (PARAM05)
A data address requested from the transmission side is output.
However, when reading/writing multiple holding registers (function code: 17H), enter a start M register number for the
address table. The four words of addresses at the beginning of the M register set by PARAM05 (data address) are used
as an address table. In this address table, read address, read size, write address, and write size requested from the trans-
mission side are output.
For more information about the address table, refer to
G.1.6 ( 7 ) Data Address (PARAM05)
on page A-58.
( 8 ) Data Size (PARAM06)
The read/write data size (number of bits or words) requested from the transmission side is output.
( 9 ) Remote CPU Number (PARAM07)
Refer to
G.2.8 Relationship between Data Address, Data Size, and Offset for MSG-RCV Function
on page A-98.
( 10 ) Offset (PARAM08, PARAM09, PARAM10, PARAM11)
Specify an offset address for the reception side data address.
The address for the reception side will be displaced by the number of words designated by the offset.
Note: 1. For more information, refer to
G.2.8 Relationship between Data Address, Data Size, and Offset for
MSG-RCV Function
on page A-98.
2. The offset cannot be a negative value.
The offset parameter is prepared for each target data type.
The following table lists the offset parameters.
The valid offset parameter may differ according to the function code.
The following table lists the valid parameters for each function code.
( 11 ) Write Range (PARAM12, PARAM13)
Sets an available address range for the write request from the transmission side. A write request which is out of this
available address range will cause an error.
Specify the address range (PARAM12, PARAM13) as a word address.
Table G.29 Offset Parameter List
Parameter
Contents
Description
PARAM08
Coil offset
Sets the coil’s offset word address.
PARAM09
Input relay offset
Sets the offset word address of an input relay.
PARAM10
Input register offset
Sets the offset word address of an input register.
PARAM11
Holding register offset
Sets the offset word address of a holding register.
Table G.30 Valid Parameter List for Offset of Each Function Code
Function Code
Function
Valid Offset
Parameter
01H
Reads coil state
PARAM08
02H
Reads input relay state
PARAM09
03H
Reads holding register content
PARAM11
04H
Reads input register content
PARAM10
05H
Changes single coil state
PARAM08
06H
Writes to single holding register
PARAM11
0FH
Changes multiple coil states
PARAM08
10H
Writes to multiple holding registers
PARAM11
16H
Mask writes to holding register
PARAM11
17H
Reads/Writes multiple holding registers
PARAM11
Содержание MP2300S
Страница 14: ...MEMO...
Страница 24: ...MEMO...
Страница 114: ...MEMO...
Страница 132: ...MEMO...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program...
Страница 190: ...MEMO...
Страница 280: ...MEMO...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page...
Страница 310: ...MEMO...