6.2 Communication with Other MP Series
6.2.3 When MP2300S Acts as Master (I/O message communication function is used)
6-39
6
Ethernet Communications
4.
Set a communication setting in the
I/O Message Communication Easy Setting
Window.
How to set up in the
I/O Message Communication Easy Setting
Window
Set
Port No.
of the MP2300S side (“10005, 10006,” X for example).
Select
Extended MEMOBUS
for
Communication Protocol Type
, and click the
Default
Button.
Caution
When the communication protocol is Extended MEMOBUS, the register type that can select both read and write is fixed at the
Holding Register (MW).
Select
Connect Type
(TCP, for example).
Select
Code
(BIN, for example).
Set
Remote IP Address
for the other device (MP2300) to be connected (“192.168.001.002,” for example).
Set
Port No.
of the other device (MP2300) to be connected (“10005, 10006,” for example).
Caution
In I/O message communication, as a message is transmitted from each port number for register read/write, a connected remote
device needs the message receive functions to receive two messages.
Содержание MP2300S
Страница 14: ...MEMO...
Страница 24: ...MEMO...
Страница 114: ...MEMO...
Страница 132: ...MEMO...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program...
Страница 190: ...MEMO...
Страница 280: ...MEMO...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page...
Страница 310: ...MEMO...