6.2 Communication with Other MP Series
6.2.2 When the MP2300S Acts as a Slave (ladder program which uses a MSG-RCV function)
6-29
6
Ethernet Communications
3.
Set connection parameters.
How to set up with a connection number 02 in the
CP-218 Connection Parameter
Window
Set
Local Port
(to the port number “10002” used in the MP2300 side, for example).
Set the
Node IP Address
(to the IP address “192.168.001.001” configured in the MP2300S side, for exam-
ple).
Set the
Node Port
(to the port number “10002” configured in the MP2300S side, for example).
Select
Connect Type
(TCP, for example).
Select
Extended MEMOBUS
for
Protocol Type
.
Select
Code
(BIN, for example).
Caution
When any transmission or connection parameter is changed, the change will be reflected after FLASH has been saved and the
power supply is turned ON again.