5.4 Self-configuration
5-35
5
Outline of Motion Control Systems
The
Engineering Manager
Window will start and the
Module Configuration
Window will appear.
2.
Right-click the Module for which devices have been added and select
Module Self Configuration
from the pop menu to execute self-configuration.
The RUN LED indicator will blink and a message indicating that
the module configuration definitions are being
created
will be dispayed. Once self-configuration has been completed, the message will disappear and the RUN
LED indicator will return to its original state.
When MP2300 is selected as an individual module, executing
Module Self Congifutation
will configure all the
modules.
3.
Select
File - Save & Save to Flash
from the main menu. A confirmation message will appear. Click
the
Yes
Button to save the module configuration definitions.