11
Battery Pack Replacement
11.1 Battery Pack Replacement
11-1
HW1485471
HW1485471
11 Battery Pack Replacement
11.1
Battery Pack Replacement
Three battery packs are installed to the position as shown in
“Location of the Battery and Multi-port Connector”
with the multi-port
connectors.
If the battery alarm appears on the programming pendant, replace the
battery pack by following one of the procedures described as follows.
Make sure to refer to
chapter 2 “Notes for Maintenance”
when replacing
the battery pack.
Fig. 11-1: Location of the Battery and Multi-port Connector
U
R
IN
OUT
Battery pack for S-, L-axes
Cable tie
Protective tube
Cable tie
Protective tube
Cable tie
Battery pack for B-, T-axes
Battery for U-, R-axes
Multi-port connector
Multi-port
connector
Cover
Fixing bolt for the cover
Cross head APS bolt M4
(length: 8 mm) (2 bolts)
Cover
Fixing bolt for the cover
Cross head APS bolt M4
(length: 8 mm) (3 bolts)
SI
N
OUT
L
B
T
IN
When the Cover is Removed
When the Cover is Removed
114/134