7 Setting and Confirming CDBR Braking Unit Operation
56
YASKAWA ELECTRIC
TOBP C720600 01E YASKAWA AC Drive Option CDBR-
D, LKEB-
Installation Manual
Table 12 CDBR Enable/Disable Status (DIP Switch S1, S4)
SINK Mode, Internal Power Supply
Set DIP switch S1 to SINK as shown in
when controlling the digital SB-SC
inputs by NPN transistors (0 V common/sinking mode) and contacts using the drive internal
power supply.
Figure 23
Figure 23 CDBR Braking Unit SINK Mode using Internal Power Supply
DIP Switch S1-SINK/
SOURCE
DIP Switch S4-SB/SC
Terminals N.O./N.C.
SB-SC-Enable Input
CDBR Status
SINK
A
Open
Enabled
SINK
A
Close
Disabled
SINK
B
Open
Disabled
SINK
B
Close
Enabled
SOURCE
A
0 V Input
Enabled
SOURCE
A
24 V Input
Disabled
SOURCE
B
0 V Input
Disabled
SOURCE
B
24 V Input
Enabled
+24 V
SINK-default
SOURCE
SB
SC
S4
S1
A (N.O. (default))
B (N.C.)
TOBP_C720600_01E_9_0_E.book 56 ページ 2017年8月25日 金曜日 午後2時8分