B.3 Parameter Table
228
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
u
d: Speed References
Speed Reference parameters are used to set the various speed reference values during operation.
n
d1: Speed Reference
No.(Addr.)
Name
Description
Setting
Page
d1-01
(280H)
Speed Reference 1
Sets the Speed reference for the drive when d1-18 is set to 0. Setting units are determined by
parameter o1-03.
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
d1-02
(281H)
Speed Reference 2
d1-03
(282H)
Speed Reference 3
d1-04
(283H)
Speed Reference 4
d1-05
(284H)
Speed Reference 5
d1-06
(285H)
Speed Reference 6
d1-07
(286H)
Speed Reference 7
d1-08
(287H)
Speed Reference 8
d1-17
(292H)
Jog Speed
Sets the frequency reference when “Jog Speed” is selected via multi-function digital input
terminals.
Default: 6.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
d1-18
(2C0H)
Speed Reference Selection Mode
Sets the mode of speed reference selection by digital inputs.
0: Use multi-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1-23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
Default: 1
Min: 0
Max: 2
d1-19
(2C1H)
Nominal Speed
Sets the nominal speed reference when d1-18 = 1 or 2.
Default: 50.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
d1-20
(2C2H)
Intermediate Speed 1
Sets intermediate speed reference 1 when d1-18 = 1 or 2.
Default: 0.00 Hz
Min: 0.00 Hz
Max: 120.00 Hz
d1-21
(2C3H)
Intermediate Speed 2
Sets intermediate speed reference 2 when d1-18 = 1 or 2.
d1-22
(2C4H)
Intermediate Speed 3
Sets intermediate speed reference 3 when d1-18 = 1 or 3.
d1-23
(2C5H)
Releveling Speed
Sets speed reference for releveling when d1-18 = 1 or 2.
d1-24
(2C6H)
Inspection Operation Speed
Sets speed reference when inspection operation is enabled.
d1-25
(2C7H)
Rescue Operation Speed
Sets the speed reference during inspection operation.
Default: 5.00 Hz
Min: 0.00 Hz
Max: 15.00 Hz
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
Содержание Lift Inverter L1000V
Страница 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 100: ...4 8 Verifying Parameter Settings and Backing Up Changes 100 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 266: ...C 5 EN81 1 Conform Circuit with one Motor Contactor 266 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Страница 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...