In order to conform to EMC standards, the exclusive-use methods are required for line filter
application, cable shielding and drive installation. The following explains the outline of the
methods.
The line filter and drive must be mounted on the same metal plate. The filter should be
mounted as close to the drive as practical. Keep cable as short as possible. The metal
plate should be securely grounded. The ground of line filter and drive must be bonded to
the metal plate with as much area as possible.
For mains input cables, screened cable is recommended at least within the panel. The
screen of the cable should be connected to solid ground. For motor cable, screened cable
(max. 20 m) must be used and the screen of the motor cable should be connected to
ground at both ends by a short connection, using as large an area as practical.
For more detailed explanation, refer to Yaskawa document TD 4077, “Installation Guidelines
For EMC Directive using Yaskawa AC Drive Products.”
Table 1-4 and Figure 1-2A show the line filter list for EMC standards and the
installation/wiring of drive and line filter.
T
Ta
ab
blle
e 1
1--4
4.. L
Liin
ne
e F
Fiilltte
errs
s ffo
orr G
GP
PD
D 5
50
06
6/
/P
P5
5
1-14
New
Old
Drive Model
Drive Model
Line Filter
Number Number Part Number
Rated
Mass Dimensions in mm
(1)
CIMR-P5M
GPD506V-
05P00325-
Current (A)
(kg)
L x W x D
(2)
40P41F
B001
40P71F
B003
0106
8
1.8
320 x 143 x 46
41P51F
B004
43P71F
B008
0103
20
1.8
320 x 143 x 46
44P01F
B011
45P51F
B014
0104
30
3.0
350 x 213 x 51
47P51F
B021
40111F
B027
0105
60
5.3
435 x 268 x 56
40151F
B034
40181F
B041
0107
80
7.5
350 x 180 x 90
40221F
B052
40301F
B065
0108
100
13.8
420 x 200 x 130
40371F
B080
0109
150
13.8
480 x 200 x 160
40451F
B096
0110
160
25
480 x 200 x 160
40551F
B128
0111
180
25
480 x 200 x 160
40750F
B180
0112
300
25
480 x 200 x 160
41100F
B240
41600F
B302
0113
400
45
588 x 250 x 200
41850F
B380
0119
500
42200F
B506
0120
600
43000F
B675
0121
900
(1) 1mm =
0.0394 inches
(2)
D is the distance the filter will extend outward from the surface of the metal plate.
1
1..4
4..3
3a
a C
Co
on
nffo
orrm
ma
an
nc
ce
e tto
o E
Eu
urro
op
pe
ea
an
n E
EM
MC
C D
Diirre
ec
cttiiv
ve
e
Consult Factory
Содержание GPD-506V
Страница 1: ...GPD 506 P5 Technical Manual Models GPD 506V and CIMR P5M Document Number TM4506...
Страница 30: ...1 17...
Страница 35: ...1 22...