PP.P5G5.03.Troubleshoot
Page 30
Rev. 06/11/2003
External fault at terminal number 3.
EF3
External Fault3
External fault at the multi-function inputs terminal
number 4 ~ 8.
EF4~8
External Fault
Possible Cause(s):
An external fault condition exists connected to terminal number 3.
Corrective Action:
Check for an external condition, verify the program parameters.
Possible Cause(s):
An external fault condition exists connected to one of the terminals 4,
5, 6, 7, or 8.
Corrective Action:
Check for an external condition, verify the program parameters.
N/A
N/A
Fault Codes
Minor Fault
- Operation continues and the digital operator indication blinks
The fault relay does not activate.
505
506
515
√