SIEPC71061737B GA800 Drive Technical Reference
Note:
•
The upper limit value changes when the
E1-04 [Maximum Output Frequency]
and
d2-01 [Frequency Reference Upper Limit]
values
change.
•
When
A1-02 = 6, 7 [Control Method Selection = AOLV/PM, CLV/PM]
, the drive changes
o1-03 = 1 [0.01% (100% = E1-04)]
.
•
This parameter sets the frequency reference of Multi-Step Speed 15.
■
d1-16: Reference 16
No.
(Hex.)
Name
Description
Default
(Range)
d1-16
(0291)
RUN
Reference 16
Sets the frequency reference in the units from
o1-03 [Frequency Display Unit Selection]
.
0.00 Hz
(0.00 - 590.00 Hz)
Note:
•
The upper limit value changes when the
E1-04 [Maximum Output Frequency]
and
d2-01 [Frequency Reference Upper Limit]
values
change.
•
When
A1-02 = 6, 7 [Control Method Selection = AOLV/PM, CLV/PM]
, the drive changes
o1-03 = 1 [0.01% (100% = E1-04)]
.
•
This parameter sets the frequency reference of Multi-Step Speed 16.
■
d1-17: Jog Reference
No.
(Hex.)
Name
Description
Default
(Range)
d1-17
(0292)
RUN
Jog Reference
Sets the Jog frequency reference in the units from
o1-03 [Frequency Display Unit Selection]
. Set
H1-
xx = 6 [MFDI Function Select = Jog Reference Selection]
to use the Jog frequency reference.
6.00 Hz
(0.00 - 590.00 Hz)
Note:
•
The upper limit value changes when the
E1-04 [Maximum Output Frequency]
and
d2-01 [Frequency Reference Upper Limit]
values
change.
•
When
A1-02 = 6, 7 [Control Method Selection = AOLV/PM, CLV/PM]
, the drive changes
o1-03 = 1 [0.01% (100% = E1-04)]
.
◆
d2: Reference Limits
d2 parameters
set the upper and lower frequency limits to control the motor speed. Apply these parameters to for
example, run the motor at low-speed due to mechanical strength concerns, or if the motor should not be run at low
speed because of lubrication issues with the gears and bearings.
The upper frequency limit is set in
d2-01 [Frequency Reference Upper Limit]
and the lower limit is set in
d2-02
[Frequency Reference Lower Limit]
.
Figure 12.61 Upper and Lower Frequency Limits
■
d2-01: Frequency Reference Upper Limit
No.
(Hex.)
Name
Description
Default
(Range)
d2-01
(0289)
Frequency Reference Upper
Limit
Sets maximum limit for all frequency references. The maximum output frequency is 100%.
100.0%
(0.0 - 110.0%)
When the frequency reference is more than the value set in
d2-01
the drive will continue to operate at the value set in
d2-01
.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA80U4720ABM
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...