42
YASKAWA
TOEP C730600 84A DeviceNet Installation Manual
2.
Connect the communication cables to the terminal block as shown in
When you attach the CN1 connector plug on the terminal block to the socket,
make sure that you tighten the screws on the left and right sides of the plug.
Tighten the screw to a correct tightening torque:
• 0.5 N
∙
m to 0.6 N
∙
m (4.4 in
∙
lb to 5.3 in
∙
lb)
3.
Make sure that you correctly connect the wires and that you did not accidentally
pinch wire insulation in the terminals.
Trim any frayed wires.
WARNING
Fire Hazard. Tighten all terminal screws to the correct tightening
torque. Connections that are too loose or too tight can cause incorrect operation and damage
to the drive. Incorrect connections can also cause death or serious injury from fire.
NOTICE
Do not let wire shields touch other signal lines or equipment. Insulate
the wire shields with electrical tape or shrink tubing. If you do not insulate the wire shields, it
can cause a short circuit and damage the drive.
A - Pull back the shielding and lightly
twist the end with your fingers to
keep the ends from fraying.
B - When you do not use crimp
ferrules, remove approximately 5.5
mm (0.21 in) of the covering at the
end of the wire.
C - Blade thickness of 0.4 mm (0.01 in)
or less
D - Up to 2.5 mm
E -
Tightening torque: 0.5 N
∙
m to 0.6
N
∙
m (4.4 in
∙
lb to 5.3 in
∙
lb)
F -
Terminal block CN1
G - DeviceNet Communication Cable
(do not solder ends)
H - Loosen the screws and put the
wire into the opening on the
terminal block.
Figure 5.29 Communication Cable Wiring