Drive Parameter Listing
(n128-n140)
Section 8
PARA-
SETTING RANGE
SETTING
FACTORY
USER
PARA.
METER
NAME
(AND UNITS)
INCREMENT
SETTING
SETTING
REF.
0:
PID control disabled
1:
D = Feed Forward
2:
D = Feedback
3:
Ref PID (D = Feed Forward)
4:
Ref PID (D = Feedback)
1
0
n128
PID Control Selection
5:
Inverse PID - D = Feed Forward
6:
Inverse PID - D = Feedback
7:
Inverse PID - Ref PID
(D = Feed Forward)
8:
Inverse PID - Ref PID
(D = Feedback)
n129
PID Feedback Gain (Note 4)
0.00 to 10.00
0.01
1.00
n130
PID Proportional Gain (Note 4) 0.00 to 25.00
0.1
1.0
n131
PID Integral Time (Note 4)
0.00 to 360.00
0.1 s
1.0
5.28
5.31
n132
PID Derivative Time (Note 4)
0.00 to 2.50
0.01
0.00
n133
PID Offset Adjustment (Note 4) -100 to 100
1%
0
n134
Integral Value Limit (Note 4)
-100 to 100
1%
100
n135
PID Output Lag Filter Time (Note 4)
0.0 to 10.0
0.1 s
1.0
Feedback Loss
0:
Disabled
n136
1:
Enabled - Alarm (operation continues)
1
0
Detection Selection
2:
Enabled Fault (coast to stop)
n137
Feedback Loss
Detection Level
0 to 100
1%
0
n138
Feedback Loss
Detection Time
0.0 to 25.5
0:
Energy saving disabled
n139
Energy Saving Selection
1:
Energy saving enabled
1
0
(Note 2)
Note: Energy saving becomes enabled by
(Energy Saving)
V/f control mode
n140
Energy Saving Gain
K2 (Energy Saving)
0.00 to 6550
0.1 or 1
(Note 1)
Drive Parameters - Continued
46
IG.V7.01_new format.qxd 4/18/05 1:21 PM Page 46
Содержание CIMR-V7xx20P1 series
Страница 4: ...4 IG V7 01_new format qxd 4 18 05 1 21 PM Page 4...
Страница 10: ...10 IG V7 01_new format qxd 4 18 05 1 21 PM Page 10...
Страница 14: ...14 IG V7 01_new format qxd 4 18 05 1 21 PM Page 14...
Страница 58: ...58 Drive Dimensions Section 10 Fig 4 W W W H1 H H2 4 d D IG V7 01_new format qxd 4 18 05 1 21 PM Page 58...
Страница 60: ...IG V7 01_new format qxd 4 18 05 1 21 PM Page 60...
Страница 61: ...IG V7 01_new format qxd 4 18 05 1 21 PM Page 61...
Страница 62: ...IG V7 01_new format qxd 4 18 05 1 21 PM Page 62...
Страница 63: ...IG V7 01_new format qxd 4 18 05 1 21 PM Page 63...