Diagnostics 3-7
Installing The
L
ON
W
ORKS
Option
This section provides a brief check of the proper installation of the
L
ON
W
ORKS
Option.
#
Drive Operates Correctly Without The
L
ON
W
ORKS
Option
Installed
Before installing any drive option,
verify that the drive functions properly without the option installed
. Refer to the appropriate drive user,
programming and/or technical manual
for information on the proper installation and operation of the drive.
#
The
L
ON
W
ORKS
Option
Is Properly Installed
!
Verify that the option card hold down on the drive had been removed prior to the installation of the
L
ON
W
ORKS
Option
.
!
Verify that the connection between 2CN on the
L
ON
W
ORKS
Option
is securely connected to and firmly seated on the 2CN connector on
the drive control board and that all stand-offs are locked in their associated mounting holes.
#
The
L
ON
W
ORKS
Option
Is Properly Connected to the Drive
!
A noise free ground is essential to the proper and stable operation of the network. Verify that the
L
ON
W
ORKS
Option
is properly
connected to a noise free ground. If a noise free ground cannot be found, leave the
L
ON
W
ORKS
Option
ungrounded.
!
Verify that the communication cable is properly and firmly seated on the J1 connector on the
L
ON
W
ORKS
Option
.
!
Select the appropriate connection diagram below. Verify:
%
that the
purple
wire is connected to the
R+
terminal on the drive’s terminal assembly,
%
that the
yellow
wire is connected to the
R-
terminal on the drive’s terminal assembly,
%
that the
orange
wire is connected to the
S+
terminal on the drive’s terminal assembly,
%
that the
blue
wire is connected to the
S-
terminal on the drive’s terminal assembly.
!
Verify that the termination switch on the drive terminal assembly is in the
ON
position.
E7, F7 and P7 Drive Connections
E7L and E7B Connections
G7 Drive Connections
Figure 3.2 – Drive Connections
#
Network Cable Is Connected Correctly
!
Connect the L
ON
W
ORKS
network cable to the
L
ON
W
ORKS
Option
. Refer to the figure below for connection details.
Figure 3.3 – L
ON
W
ORKS
Network Connections
Содержание CIMR-E7 series
Страница 1: ...LONWORKS Option Technical Manual Models CIMR E7 P7 F7 and G7 Document Number TM AFD 20 ...
Страница 5: ...iv This page intentionally left blank ...
Страница 7: ...Installation 1 2 This page intentionally left blank ...
Страница 9: ...Installation 1 4 This page intentionally left blank ...
Страница 19: ...Application Overview 2 2 This page intentionally left blank ...
Страница 38: ...Diagnostics 3 2 This page intentionally left blank ...
Страница 40: ...Diagnostics 3 4 This page intentionally left blank ...