44
Fault/malfunction
Cause
Remedy
Product not running.
No electrical voltage at the
device
Check the fuse , power cable ,
power plug and mains socket
and have them replaced by
qualified personnel if necessary
The mains voltage is lower than
that specified
Contact the power supply
company if necessary
Cross section of the extension
cable no large enough and /or
the extension cable is too long.
Use extension cable with larger
cross sections and/or use shorter
extension cable.
Forward/ reverse button be set to
wrong position.
Set it to upper position.
when the motor stop running,
due to overload. The reset button
is activated.
Before restart, depress the reset
button
Internal wiring of machine
damaged
Contact service partner.
Motor is damaged
Contact service partner.
Switch is damaged
Contact service partner.
Vibration and abnormal noise
Fixing screws are loose
Tighten the relevant parts
Cutting head are damaged
Contact service partner
Chips cannot meet requirement,
it is not small enough
Blades are blunt or totally
damaged.
Contact service partner