CH1900 Series Electronic Control Installation Manual
Page 8
Mounting Instructions
Mounting the Operators Panel (CP1200)
Determine a Proper Mounting Location
The CP1200 Operator Panel is designed to be mounted on flat surfaces convenient for both operation and
installation. The panel is designed to mount on surfaces from 1/4 inch (6 mm) to 1 inch (25 mm) thick with the
hardware provided.
Mount the Operator Panel
Mount the CP1200 Operator Panel Template from the back of this manual to the chosen mounting surface.
Caution: Before using a template from this manual, measure it to be certain it is to scale.
1. Mark the mounting surface for hole placement using the template. Drill four mounting holes and switch center
hole.
2. Secure operator panel to the mounting surface with four # 10 x 1-1/2 inch (38 mm) long mounting screws,
washers, and locking nuts provided.
Mount the Control Interface
(see page 12 for diagram)
While the CH67019D can be mounted horizontally or vertically, the preferred mounting is vertical with the
connectors facing down.