Yanmar
®
600 Control Panel Operation and Troubleshooting
463-3000-09 Initial - 16-May-2008
13
System Menu
The
System Menu
allows the user to configure items affecting how the system functions. . Button 4
cycles
through the available values for the selected item.
Demo
The display supports several demo modes to
operate with simulated data. Mode 1 simulates
speed data and engine parameters. Mode 2 only
simulates engine parameters. Mode 3 simulates
speed data, engine parameters and alarms. Mode
0 disables Demo Mode. Demo is automatically
set to 0 (Off) if live data is received.
Restore Defaults
This allows resetting all configuration information
to default US
or Metric
units. Additionally
the display is reset to the initial configuration.
The default settings are:
Setting
US
Metric
Language
English
Button Beep
On
Service Timers
Off
Display Mode
Analog Gauges
Gauge Pages
Defaults
Quad Adjust
On
Demo Mode
0 (Off)
Engine Source
0
Display CAN Address
40
Alarm Filter
Glb
SPN Version
1
Speed Source
Auto
PIN Entry
Off
PIN
1111
Max Gauge RPM
2500
Max Gauge Speed
40 MPH 60 km/h
Speed Units
MPH
km/h
Distance Units
Miles
km
Pressure Units
PSI
kPa
Volume Units
Gal
l
Temperature Units
ºF
ºC
Содержание CANplus 600
Страница 34: ...Yanmar 600 Control Panel Operation and Troubleshooting 34 463 3000 09 Initial 16 May 2008 ...
Страница 36: ...Yanmar 600 Control Panel Operation and Troubleshooting 36 463 3000 09 Initial 16 May 2008 ...
Страница 39: ...Yanmar 600 Control Panel Operation and Troubleshooting 463 3000 09 Initial 16 May 2008 39 ...