Service - 76
SK1550 Operator’s Manual
Procedures
Belt, Fan
Check at 50 hours and every 250 hours thereafter.
Adjust tension as needed. Change every 500
hours.
Check
Check for excessive slack, damage, or wear. Belt is
properly tensioned when it moves about 1/4-3/8”
(7-9mm) when pushed at long span (shown).
Adjust Tension
1. Loosen two alternator bolt (1, 2).
2. Adjust position as needed.
3. Tighten bolts.
4. Check tension.
Change
1. Loosen two alternator bolts (1,2).
2. Replace fan belt.
3. Adjust position as needed.
4. Tighten bolts.
5. Check tension.
1
2
t53om037w20.eps
Содержание 3TNV86C
Страница 1: ...SK1550 Yanmar 3TNV86C Operator s Manual CMW 053 2996 Issue 2 0 Original Instruction ...
Страница 19: ...Safety Awareness 18 SK1550 Operator s Manual Machine Safety Alerts ...
Страница 49: ...Controls 48 SK1550 Operator s Manual Operator Station ...
Страница 55: ...Drive 54 SK1550 Operator s Manual Shut Down ...
Страница 63: ...Transport 62 SK1550 Operator s Manual Retrieve ...
Страница 91: ...Service 90 SK1550 Operator s Manual Procedures ...
Страница 97: ...Specifications 96 SK1550 Operator s Manual Declaration of Conformity ...