background image

 

 

 

Cautions in Using with Safety 

Table of Illustrated Symbols 

 

 

Warning

 

 

 

 

 

 

Warning 

generally 

Warning 

high voltage 

Warning 

high temperature 

Warning 

drive train 

Warning 

explosive 

 

 

Caution 

 

 

 

 

 

Caution 

generally 

Caution 

electrical shock 

Caution 

scald 

Caution 

no road heating 

Caution 

not to drench 

 

 

 

 

 

Caution 

water only 

Caution 

deadly poison 

 

 

 

 

 

Prohibit 

 

 

 

 

 

Prohibit 

generally 

Prohibit 

inflammable 

Prohibit 

to disassemble 

Prohibit 

to touch 

 

 

 

Compulsion 

 

 

 

 

 

Compulsion 

generally 

Compulsion 

connect to the 

grounding terminal 

Compulsion 

install on a flat 

surface 

Compulsion 

disconnect the power 

plug 

Compulsion 

periodical 

inspection 

Содержание SK102C

Страница 1: ...ing Sterilizer SK Series of Yamato Scientific Chongqing Co Ltd To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit fo...

Страница 2: ...hodU3T 12 3TUApparatus Liquid Sterilization CourseU3T 12 3TUSterilizing ParametersU3T 16 3TUHandling PrecautionsU3T 17 3TU WARNINGU3T 17 3TUCAUTIONU3T 18 3TUMaintenance MethodU3T 19 3TUDaily Inspectio...

Страница 3: ...ger of a problem that may cause a serious accident or even fatality CAUTION If the caution is ignored there is the danger of a problem that may cause injury damage to property or the unit itself Meani...

Страница 4: ...ution electrical shock Caution scald Caution no road heating Caution not to drench Caution water only Caution deadly poison Prohibit Prohibit generally Prohibit inflammable Prohibit to disassemble Pro...

Страница 5: ...ock may result Never perform repair work yourself since it is dangerous and not recommended Do not use the power cord if it is bundled or tangled Do not use the power cord if it is bundled or tangled...

Страница 6: ...ins very hot just after the sterilizing operation has completed even the pressure reading is 0 zero MPa Drain the water after it is sufficiently cooled down Do not touch the hot section Some sections...

Страница 7: ...ntal surface The power source is instable Install this unit on a stable place with the space as shown below 2 Installation on horizontal surface Use the equipment on the horizontal and firm place to k...

Страница 8: ...eptacle Choose a correct power distribution board or receptacle that meets the unit s rated electric capacity Operating voltage range for respective equipment models are as follows SK102C models AC115...

Страница 9: ...le of power cord to the grounding conductor or ground terminal to prevent accidents caused by electric leakage Do not connect the earth wire to gas or water pipes If not fire disaster may be caused Do...

Страница 10: ...filled 3 Use distillated or purified water for sterilizing water Fill distillated or purified water inside the chamber Tap water may be used Calculus generate inside the chamber when tap water is used...

Страница 11: ...d the safety lock to remain in open position and the safety lock will lock the upper and lower handles automatically when the pressure in pot rises The lock lever on the cover is held by the hook and...

Страница 12: ...f Each Part Main Unit No Name No Name 1 Safety valve 6 Upper cover 2 Vent valve 7 Operation panel 3 Handle up down 8 Power switch 4 Exhaust drain valve 9 Exhaust drain port 5 Pressure gauge 10 Power i...

Страница 13: ...ights up 7 Working lamp The indicator lamp is ON when the RUN key is pressed and the product starts to work 8 Increase Decrease keys Press Up to increase the parameters to be modified and press Down t...

Страница 14: ...the handle and the heater will not work when the cover is not closed or there is water shortage in cylinder The blinking water level lamp indicates that there is water shortage in the cylinder Figure...

Страница 15: ...ears in the display screen Figure 14 Press the up and down keys Figure 15 to adjust the required sterilization time value After the adjustment press the set key twice to store and confirm the new ster...

Страница 16: ...perature and pressure rising Figure 19 When the temperature in the cylinder rises to be about 102 the interlock indicator lamp will turn to be normally ON Figure 20 When the temperature of sterilizer...

Страница 17: ...uge returns to zero Figure 26 turn the cover CCW and separate the upper and lower handles completely Figure 27 At this point the interlock lamp goes out Figure 28 indicating that the cover can be remo...

Страница 18: ...ation with the target setting temperature Check the temperature in furnace temperature of sample with a thermograph after it is stabilized Check the difference between the setting temperature and that...

Страница 19: ...for flammability and handling of flammable solvent This unit is not designed as the explosion proof construction Pay special attention to the handling of the sample to be handled with this unit on the...

Страница 20: ...y Drain the water after the water is sufficiently cooled down Do not drain water during operation The hot water blows out if the drain valve is opened while the pressure is increasing Do not damage th...

Страница 21: ...rmal state Do not disassemble this unit U CAUTION Use a well drained soft cloth to wipe dirt on this unit Do not use benzene thinner or cleanser for wiping Do not scrub this unit Deformation deteriora...

Страница 22: ...you to disassemble this unit as possible and recycle the reusable parts considering to the environmental protection The feature components of this unit and materials used are listed below Component N...

Страница 23: ...blocked 2 the safety valve unable to work properly 1 to unclog the safety valve 2 to replace the safety valve with qualified one 4 The pressure gauge failing to return to zero under non pressure condi...

Страница 24: ...les office Check following items before contact Model Name of Product Production Number Purchase Date About Trouble in detail as possible Minimum Retention Period of Performance Parts for Repair The m...

Страница 25: ...s Fixed temperature operation procedure Safety devices Water level detection liquid expansion method safety valve 0 165MPa safety interlocking interactive device spring full lift safety valve Pressure...

Страница 26: ...iagram SK102C 201 301C Symbol Part name Symbol Part name ELB Power switch SMJ1 Control board FU3 Safety tube SMJ2 Display board H1 Heater Pt100 Temperature sensor BL Float Switch SW1 Cover interlock s...

Страница 27: ...iagram SK112C 211 311C Symbol Part name Symbol Part name ELB Power switch SMJ1 Control board FU3 Safety tube SMJ2 Display board H1 Heater Pt100 Temperature sensor BL Float Switch SW1 Cover interlock s...

Страница 28: ...0019 8808049 50 White YSJ Caster With brake A080300019 8808062 50 White TM Terminal block A011302002 T3052 6 4P CLO YSJ SK102C 201 301C Symbol Part Name Code No Specification Manufacturer SMJ1 CONT bo...

Страница 29: ...te Ammonium perchlorate and other perchlorate Potassium peroxide Sodium peroxide Barium peroxide and other inorganic peroxide Potassium nitrate Sodium nitrate Ammonium nitrate and other nitrate Sodium...

Страница 30: ...cument may be changed in future without notice Any books with missing pages or disorderly binding may be replaced Sales Yamato Scientific America Inc 925 Walsh Ave Santa Clara CA 95050 Yamato Scientif...