YCO-1049-02-03
PPC-200W
Technical Manual
IV Parameter Lists
IV.C Factory Parameters
9
Key Function Description
Word
56 Location of decimal point 000 0 (No decimal point.)
001 0.0
002 0.00
003 0.000
004 0.0000
57 Type of decimal point 000 Period (.)
001 Comma (,)
58 Weighing unit 000 No unit.
001 g
002 kg
003 lb.
004 oz.
59 Weighing unit display 000 No display.
001 Specifi ed unit displayed.
60 Weighing capacity base value 000 Not used in pound mode.
(pound mode) 001~099
61 Weighing capacity index value 000~004
(pound mode)
62 Location of decimal point <Decimal pound and decimal ounce modes>
(lb , oz or lb/oz mode) 000 0 (No decimal point)
001 0.0
002 0.00
003 0.000
004 0.0000
<Pound/ounce mode>
000 0 : 0.00
001 0 : 0.0
002 0 : 0
003~004 Not used.
63 Pound increment 000~008
64 Pound conversion coeffi cient 000 Conversion coeffi cient = 1.00000
001 Conversion coeffi cient = 0.705479
002 Conversion coeffi cient = 0.881849
003 Conversion coeffi cient = 1.10231
65 Zero point range 000~100
66 Zero point range on plus side 000~100
67 Over scale 000~010
68 Display hold function 000 No hold
001 Hold for weight more than net + 10 divisions.
002 Hold for weight more than net + 10 divisions, hold key invalid.
003 Hold for weight more than net + 20 divisions.
004 Hold for weight more than net + 20 divisions, #10 invalid.
005 Hold for weight more than net + 20 divisions, hold key invalid,
#10 invalid.
69 Hold release against 000 Hold against any increased weight.
increased weight 001~005 Hold release against a specifi ed increase.
70 Stable mark 000 Display the stable mark.
001 Stable mark not displayed.