IV Changing the Scale Setup
Parameter Descriptions - Factory Parameters
Key Function Description
Word
51 Scale mode 000 Fixed single increment.
001 Multi-increments.
002 Do not use.
003 Do not use.
004 Change-over / gram mode - decimal pound mode.
005 Change-over / gram mode - lb/oz mode.
006 lb/oz mode.
007 Change-over / gram mode - continuous ounce mode.
52 Multi-increments, 000 Fixed single increment.
complex increment mode 001 Fixed accuracy, 3 increments.
002 Fixed accuracy, 2 increments.
003 Increment change at 50% full scale, 2 increments.
004 Increment change at 80% full scale, 2 increments.
005 Increment change at 64% full scale, 2 increments.
006 Increment change at 40% full scale, 2 increments.
53 Weighing capacity base value 000~099
54 Weighing capacity index value 001~004
55 Increment for lighter range 000 1
001 2
002 5
003 10
004 20
005 50
006 100
007 200
56 Location of decimal point 000 0 (No decimal point.)
001 0.0
002 0.00
003 0.000
004 0.0000
57 Type of decimal point 000 Period (.)
001 Comma (,)
58 Weighing unit 000 No unit.
001 g
002 kg
003 lb.
004 oz.
59 Weighing unit display 000 No display.
001 Specified unit displayed.
60 Weighing capacity base value 000 Not used in pound mode.
(pound mode) 001~099
61 Weighing capacity index value 000~004
(pound mode)
Содержание DP-6200
Страница 4: ...YCO 1112 04 06 DP 6200 Technical Manual II Description 2 FIG 1 FIG 2 FIG 3 Name and Function of Parts ...
Страница 21: ...YCO 1112 04 06 DP 6200 Technical Manual VI Wiring Diagram 19 ...
Страница 22: ...YCO 1112 04 06 DP 6200 Technical Manual VIIParts List 20 ...
Страница 23: ...YCO 1112 04 06 DP 6200 Technical Manual 21 VII Parts List ...
Страница 24: ...YCO 1112 04 06 DP 6200 Technical Manual 22 VII Parts List ...