9
DP-6100 GP
Technical Manual
8)
Remove (2) upper screws from base collar and (1) from
indicator collar to free column.
Remove and lay indicator/column assembly on counter.
9)
Open indicator housing by pulling tab, located on back of
housing, forward.
IMPORTANT:
Be careful not to scratch display window.
Lay on soft surface (towel, pad, etc...).
10)
Remove Wire Cover (2 screws) and Battery Housing (2
screws). Battery Housing is connected by two wires
and does not need to be completely removed.
11)
The load cell cable is now visible from behind Battery
Housing. It emerges out of back of indicator housing.
Six colored wires come out of this cable: yellow, black,
green, white, red, and yellow with a green stripe. At the
end of the colored wires is a flat, 7-pin connector.
Unhook this connector and unscrew ground wire which
is attached to indicator housing.
12)
Thread Load Cell Cable through small, rectangular hole
at back of indicator housing. Remove and retain black,
rectangular gasket.
13)
Remove indicator from Column (and cable) and pull
Cable from inside Column.
14)
Remove Base Collar Cover (1 screw) from the underside
of Base Collar. To access Cover, platform must be
tilted.
15)
Feed Cable through Base Collar and pull Cable through
round rubber seal in platform base.
Note:
Base Collar does not need to be remove from
platform.
16)
Load cell in now free to be removed.
REPLACING LOAD CELL
Column
Load Cell
Cable
Base Collar
Base Collar
Cover
Installing Load Cell:
1)
Installing load cell is reverse of removal, except mounting load cell to spiders first is recommended.
Important:
-Ensure upper and lower spider are aligned and straight before tightening.
-Torque load cell bolts to 115 ft-lb.
Reminders:
-The longer load cell bolts go through the load cell into the lower spider.
-Do not forget to connect ground wire.
-The end of column with drilled hole goes into base collar.
-Hide wires neatly under wire cover and battery housing.
Battery Housing
Wire Cover