18
DP-6100 GP
Technical Manual
Keyword
Parameter
Function
Description
#
Value (STD)
55
004
polarity stability width
000: 0 count
~~~: ~~~ counts
255: 255 counts
56
032
zero tracking
000: disabled
001: 1 tracking/1 sample
~~~: 1 tacking/~~~ samples
255: 1 tracking/255 samples
57
001
increment changeover
000: no
001: yes
58
***
scale capacity
000: 30 kg
(see indicator housing)
001: 60 kg
002: 150 kg
003 - 009: do not use
010: 60 lb/30 kg
011: 150 lb/60 kg
012: 300 lb/150 kg
59
001
signs
000: Japanese market
001: US market
002: other markets
60
001
zero reset during taring
000: enabled
001: disabled
61
004
not used
62
000
not used
63
004
not used
68
000
not used
69
000
preset tare
000: enabled
001: disabled
70
***
gravity compensation
001 - 016: do not use
use equation to
value = local gravity (m/s^2)
calculate value
x 1000 - 9700 (enter below)
017: value = 17
~~~: value = ~~~
150: value = 150
72
000
min. value
000: 20d
printed
001: 1d
0~~: ~~d
099: 99d
73
000
new software
74
000
new software
000: no
76
001
temp. conpensation
001: yes
APPENDIX A: KEYWORD PARAMETER VALUES