6
When using this machine with ventilation (with Damper opened) it is required to make
sure of full ventilation around the place. Without enough ventilation around the machine a
hot flats from its exhaust opening will raise room temperature or the room can be filled with
smoke and gas discharged from its materials. Therefore do not forget to connect an exhaust
duct at its exhaust opening in order to discharge a blast wind outside. We can offer exhaust
pipe flange and exhaust dust as an option by request.
BEFORE USING IT
REQUIREMENTS FOR INSTALLATION
WARNING
4
.
Choose a correct power distribution board.
・
Choose a correct power distribution switchboard or receptacle that meets the oven’s
rated electric capacity.
Electric capacity
:
Model DF411
AC200V
Single phase
11A
Model DF611
AC200V
Single phase
16A
Model DH411
AC200V
Single phase
14A
Model DH611
AC200V
Single phase
20A
・
Do not connect the oven to an outlet that differs from the above specifications because a fire or
electrical shock will occur
5. Supply connections for the oven
・
Request the supply connection for the 200V specifications from a licensed electrician.
・
Failure to have this operation complete by certified personnel will cause a fire or
electrical shock during Oven operations.
6. Do not use the unit in an area where there is flammable or explosive gas.
・
Never use the unit in an area where there is flammable or explosive gas.The unit is
not explosion-proof. An arc may be generated when the power switch is turned ON or
OFF,and fire/explosion may result.