YCO-1047-03-13
PPC-200(W)
Operation Manual
6
III Directions for Use
III.H Weighing
III.H.4 Batching (continued)
5) Continue in this manner until all items to be batched have been
weighed. Do not allow the gross weight on the scale platform to
exceed the capacity of the scale.
6) Remove all items from the scale platform and press the
key.
IV Entering User Parameter Mode
If the PPC‑200W is configured for legal for trade use (system parameter 40 set to 003, CAL indicator is
off), then keypad entry to user parameter mode will be disabled. When the PPC‑200W is configured
for legal for trade use, then entry to all parameter setting modes requires the scale to be opened
and the test jumpers to be shorted to enter Test Mode.
System parameter 40 must be set to 000 or 002 to enable keypad entry to user parameter mode. This
will also activate the CAL annunciator, indicating that the scale is not properly configured for legal
for trade operation. For more information on setting system parameters and entering Test Mode,
please see the PPC-200W Technical Manual.
1. Turn scale on. Press
and
to enter User
Parameter Mode. The scale will indicate a keyword fol-
lowed by it’s value.
2. To select the desired keyword, use the keys as follows:
- increase keyword by one
+
- decrease keyword by one
Note: Use the User Parameter List in Section VII to
locate the function to be changed and it’s standard value.
Example: To select lb/kg priority at power on press
nine times.
Keyword
Parameter Value
III.I CAL Indicator
If the CAL indicator is lit, the PPC‑200W has not been configured to be sealed for legal for trade use.
System parameter 40 must be set to 003 for all legal for trade applications. For instructions on
changing the system paramenters, please see Section IV Changing the Scale Setup in the PPC-
200W Technical Manual.