background image

YCO-1047-03-13

PPC-200(W)

 

Operation Manual

Remove everything from the platform surface and press the 

 key. The display will briefly flash all the LCDs.  After approxi

-

mately 5 seconds, the display will stop flashing and automati

-

cally set to zero.

III  Directions for Use

III.A  Installing Batteries or AC adaptor

Remove the stainless steel platform. Gently and carefully turn the scale on it's side.  Ensure the surface 

around the battery cover is dry.  Do not allow water to enter the battery compartment.  Turn the bat-

tery cover thumbscrew counterclockwise until it comes free.  Swing the cover open.  Install the bat-

teries according to the polarity markings. If you reverse the polarities of the batteries, the scale will 

be damaged. Swing the battery cover into place and insert the thumbscrew.  Tighten the thumbsrew 

securely.  If the battery cover is loose, the washdown seal will leak.

Use only the AC adaptor specified for use with the scale. Using the wrong adaptor can damage the 

scale.  Remove the battery cover and the batteries, if installed.  Replace the battery cover.  Remove 

the washdown plug from the jack.  Insert the adaptor plug securely into the jack.  Do not washdown 

the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack.

III.B  Leveling the Scale

Place the scale on a flat and level surface.  If the scale is not level, the readings may 

not be accurate.  You can check whether the scale is level by using the bubble 

level device positioned on the left front surface of the scale.  Adjust the feet by turn-

ing them in or out to lower or raise the corner of the scale the foot is on.

III.C  Turning the Scale On and Off

Press the 

 key.  The display will

 

go off.  Under battery operation, the power will

 

be shut off auto-

matically (AutoOff function) after about 15 minutes of non-use, even if you don’t press the 

 key.

2

III.D  Checking the Battery Level

Turn the scale on and push the 

 key while the display is flash

-

ing.  The remaining battery life will be displayed.  The more “o” 

you see, the more life there is left in the batteries.  After a few 

seconds, the scale will go to weighing mode.

III.E  Zero the Display

The scale will zero automatically when turned on.  If a value is displayed when the platform is empty, 

push the 

 key to zero the display.  The maximum zero range during power up is approximately

 

± 1.9% of the scale capacity.

III.F  Switching Between LB and KG

To switch between LB and KG, press and hold the 

 key and press the 

 key.

Содержание Accu-weigh PPC-200

Страница 1: ...PORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 PPC 200W WASHDOWN PPC 200 SPLASH PROOF Version 5 00 ...

Страница 2: ...the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the plat form or drop it the scale may be damaged and lose accuracy 4 If the scale becomes dirty wipe it with a soft cloth For stubborn stains apply a little neutral detergent and then wipe the scale with a dry cloth Do n...

Страница 3: ...le 2 C Turning the Scale On and Off 2 D Checking the Battery Level 2 E Zero the Display 2 F Switching Between LB and KG 2 G Setting the Over Under Indicator 3 H Weighing 4 1 Using the Over Under Indicator 4 2 Gross Weighing 4 3 Net Weighing 5 4 Batching 5 I CAL Indicator 6 IV Entering User Parameter Mode 6 V Optional Analog Meter 8 VI Troubleshooting and Error Messages 10 VII User Parameter 11 ...

Страница 4: ...r legal for trade operation 14 Battery Cover Tighten securely to maintain washdown seal 15 Outlet of AC adaptor cable Use of an AC adapter voids washdown seal 16 Levelling Legs Rotate to level the scale Fig 1 Front side of the scale Fig 2 Bottom of the scale 1 Weighing system Strain gauge load cell Platform 9 x 9 230 x 230 mm stainless steel Weight display Single face display Type 7 segment LCD Ch...

Страница 5: ... securely into the jack Do not washdown the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack III B Leveling the Scale Place the scale on a flat and level surface If the scale is not level the readings may not be accurate You can check whether the scale is level by using the bubble level device positioned on the left front surface of the scale Adjust the fe...

Страница 6: ...e indicated as under 6 Press and hold the key and push the key Yellow Cor ners This saves the lower limit and moves to the upper limit 7 Press the key to select the digit you want to change 8 Press the up and down arrows to select the desired value 9 Repeat steps 7 and 8 until all digits are set All values above this setpoint will be indicated as over 10 Press and hold the key and push the key Yel...

Страница 7: ...less than the under setpoint the large under arrow will appear 3 If the item weighs from the lower setpoint to the upper setpoint inclusive the accept bullseye will appear 4 If the item weighs more than the upper setpoint the large over arrow will appear 4 III H 2 Gross Weighing 1 Begin with no load on the scale the display reading zero and the center zero and stable indicators lit 2 Place the ite...

Страница 8: ...eight of the item s and the container Press the key again to return to the net weight 5 To return to gross weighing mode remove all items from the scale platform and press the key III H 4 Batching 1 Begin with no load on the scale the display reading zero and the center zero and stable indicators lit 2 Place an empty container on the scale platform and press the key The weight of the container wil...

Страница 9: ...ameter mode This will also activate the CAL annunciator indicating that the scale is not properly configured for legal for trade operation For more information on setting system parameters and entering Test Mode please see the PPC 200W Technical Manual 1 Turn scale on Press and to enter User Parameter Mode The scale will indicate a keyword fol lowed by it s value 2 To select the desired keyword us...

Страница 10: ...anual 7 IV Entering User Parameter Mode 3 To change a parameter value use the keys as follows increase value by one increase value by ten decrease value by one decrease value by ten 4 Press to save changes and press to exit User parameter ...

Страница 11: ...st and the indicator will move to the under range 2 Use the and keys to align the indicator with the low end of the under range 3 Press the key The indicator will move to the over range 4 Use the and keys to align the indicator with the high end of the over range 5 Press the key to save the calibration and to return to normal weighing mode V Optional Analog Meter WARNING The PPC 200W is NOT WASHDO...

Страница 12: ...until the entire number is set 5 Press the key again to save the displayed under setpoint and to display the current over setpoint 6 Press the key to select the digit you want to change 7 Press the or keys to set the desired value 8 Repeat steps 6 and 7 until the entire number is set 9 Press the key to save the displayed upper setpoint and to return to normal weighing mode This sets the register A...

Страница 13: ...played It is usually displayed when the plat form is removed or has something wedged under it 4 Initial error on startup When the initial weight is heavier than the permissible zeroing range and the key is pressed this message will be dis played Remove whatever is on the platform and press the key again When the initial weight is lighter than the permissive zeroing range and the key is pressed thi...

Страница 14: ... weight gross weight 1 batch 002 Net weight tare weight gross weight 3 batches 003 Display content 1 batch 004 Serial printer format 1 batch 05 000 Communication speed 000 9600 bps 001 600 bps 002 1200 bps 003 2400 bps 004 4800 bps 005 9600 bps 006 19200 bps 007 38400 bps 06 000 Character length 000 8 bits 001 7 bits 07 002 Parity 000 Non 001 Odd 002 Even 08 001 Stop bit length 000 1 bit 001 2 bit...

Отзывы: