Wiring Connection of Auxiliary Switches / Auxiliary Potentiometer 

Figure 15.    Wiring connection of auxiliary switches/auxiliary potentiometer 

 

 

••••

 Connection of auxiliary switches 

OP1 

OP2 

OP3 

OP4 

OP5 

OP6 

Part No. 83161792-001 

Terminal block 

Auxiliary switch 1 

(Adjustable between   

0 % to 50 % positions) 

Auxiliary switch 2 

(Adjustable between 

50 % to 100 % positions) 

••••

 Connection of auxiliary potentiometer 

NC 

NO 

Common 

NC 

Common 

NO 

OP1 

OP2 

OP3 

Close 

Open 

Part No. 83161793-001 

Terminal block 

Auxiliary  

potentiometer 

Содержание ACTIVAL VY51XXJ

Страница 1: ...n combination with a proportionally controlled electronic controller The nominal resistance 135 input provides proportional control in combination with a proportionally controlled electric controller...

Страница 2: ...equipment damages Flush the piping so that no foreign substance remains Attach a strainer at upstream side of the piping to prevent equipment damages After the piping installation make sure no fluid...

Страница 3: ...teel JIS SCS13A for large raised face RF type Plug and stem Stainless steel equivalent to JIS SCS Seat ring Heat resistant PTFE Gland packing Inorganic fiber Gasket Non asbestos joint sheet Piping con...

Страница 4: ...Cover Plastic polycarbonate resin color gray Yoke Steel plate Surface finishing Case None Yoke Electro galvanizing bright chromate finish Installation locations Indoor Outdoor keep away from direct s...

Страница 5: ...ctuator label and the wiring diagram label as follows Nominal 135 feedback potentiometer Nominal 135 resistance input 4 mA DC to 20 mA DC input 2 V DC to 10 V DC input Actuator valve Actuator Valve Ba...

Страница 6: ...12 15 4 4 6 25 127 60 229 90 125 90 67 14 19 4 6 6 40 165 82 5 242 103 140 105 81 16 19 4 10 0 50 178 89 246 107 155 120 96 16 19 4 11 5 65 190 90 267 129 175 140 116 18 19 4 16 80 203 100 268 130 185...

Страница 7: ...nspection Figs 1 and 2 show the minimum clearance for maintenance and inspection When installing the ACTIVAL in a ceiling space place a drain pan under the valve 3 Install a bypass pipe and gate valve...

Страница 8: ...ully open position to the piping Step 1 in Fig 6 3 Remove the screws connecting the yoke and the valve body Step 2 in Fig 6 4 Change the direction of the yoke to the desired direction The actuator can...

Страница 9: ...ing of 4 20 mA DC input and 2 10 V DC input refer to Figs 12 to 14 and make sure the polarity of power supply and 2 10 V DC output Incorrect wiring may result in PCB printed circuit board burnout To p...

Страница 10: ...cted inside of the actuator Figure 13 Wiring terminal diagram Model VY514XJ00XX 2 10 V DC input with 2 10 V DC output type Note The terminals 2 5 and 7 are connected inside of the actuator Model VY511...

Страница 11: ...esistance input B R T1 T2 Neostat Model TY900XZ Transformer Power supply W B R Connection with Model R35TC0 Model R36TC0 Power supply Model R35TC0 Model R36TC0 Model VY513XJ 4 20 mA DC input with 2 10...

Страница 12: ...nnection of auxiliary switches OP1 OP2 OP3 OP4 OP5 OP6 Part No 83161792 001 Terminal block Auxiliary switch 1 Adjustable between 0 to 50 positions Auxiliary switch 2 Adjustable between 50 to 100 posit...

Страница 13: ...e Misaligned piping Tighten the flange bolts Replace the gasket Redo piping Fluid leaks from the gland part Loosened gland packing Tighten the gland nut Fluid leaks from the bonnet Loosened bolts Tigh...