AB-6464 

Safety Instructions 

Please read instructions carefully and use the product as specified in this manual.    Be sure to keep this manual nearby 
for ready reference. 

Usage Restrictions   

This product is targeted for general air conditioning.    Do not use this product in a situation where human life may be 
affected.    If this product is used in a clean room or a place where reliability or control accuracy is particularly required, 
please contact Yamatake’s sales representatives.    Yamatake Corporation will not bear any responsibility for the re-
sults produced by the operators. 

 

 CAUTION 

 

  Installation must be performed by qualified personnel in accordance with all applicable safety standards. 

 

  This product must be operated within its operating ranges specified in this manual.    Failure to comply will 

cause equipment damages. 

 

  Installation must be carried out under the operating conditions specified in this manual to prevent equip-

ment damages. 

 

  For storage, do not stack too many container boxes in which products are packed.

 

 

  Do not put heavy load on the actuator.

 

 

  Do not leave the controlled fluid frozen.    Equipment damages and leakage may occur.

 

 

  Make sure the flow direction and install the product in the direction and position specified in this manual. 

Excessively tight connection of piping and improper installation position may cause equipment damages.

 

 

  Flush the piping so that no foreign substance remains.    Attach a strainer at upstream side of the piping to 

prevent equipment damages.

 

 

  After the piping installation, make sure no fluid leaks from the connecting parts.

 

 

  Use a full gasket for the flat face flange to prevent equipment damages or control fluid leakage.

 

 

  Do not install the product in a location adjacent to a steam coil or a hot-water coil.    High temperature ra-

diation may result in an actuator malfunction.

 

 

  Avoid instrumentation that keeps equipment operating cycle excessively frequent so as not to shorten the 

equipment operating life.

 

 

  When this product is used with a controller of another manufacturer, contact Yamatake’s sales represen-

tatives.

 

 

  All wiring must comply with local codes of indoor wiring and electric installation rules.

 

 

  Disconnect the power supply before performing any wiring to prevent electrical shock or equipment dam-

ages.

 

 

  Use crimp terminals with insulation for electric wires.

 

 

  Make sure all the wires are tightly connected to prevent heat generation and equipment damages.

 

 

  Do not disassemble the product at any time except when removing the cover to wire or replacing a part to 

prevent equipment damages.

 

 

  Do not incinerate this product for waste disposal.    Do not recycle all or a part of this product, either.

 

 

  Dispose of this product as industrial waste in accordance with the local regulations. 

 
Trademark information: 
ACTIVAL, Infilex, Neostat are trademarks or registered trademarks of Yamatake Corporation in Japan or other countries. 

Содержание ACTIVAL VY51XXJ

Страница 1: ...n combination with a proportionally controlled electronic controller The nominal resistance 135 input provides proportional control in combination with a proportionally controlled electric controller...

Страница 2: ...equipment damages Flush the piping so that no foreign substance remains Attach a strainer at upstream side of the piping to prevent equipment damages After the piping installation make sure no fluid...

Страница 3: ...teel JIS SCS13A for large raised face RF type Plug and stem Stainless steel equivalent to JIS SCS Seat ring Heat resistant PTFE Gland packing Inorganic fiber Gasket Non asbestos joint sheet Piping con...

Страница 4: ...Cover Plastic polycarbonate resin color gray Yoke Steel plate Surface finishing Case None Yoke Electro galvanizing bright chromate finish Installation locations Indoor Outdoor keep away from direct s...

Страница 5: ...ctuator label and the wiring diagram label as follows Nominal 135 feedback potentiometer Nominal 135 resistance input 4 mA DC to 20 mA DC input 2 V DC to 10 V DC input Actuator valve Actuator Valve Ba...

Страница 6: ...12 15 4 4 6 25 127 60 229 90 125 90 67 14 19 4 6 6 40 165 82 5 242 103 140 105 81 16 19 4 10 0 50 178 89 246 107 155 120 96 16 19 4 11 5 65 190 90 267 129 175 140 116 18 19 4 16 80 203 100 268 130 185...

Страница 7: ...nspection Figs 1 and 2 show the minimum clearance for maintenance and inspection When installing the ACTIVAL in a ceiling space place a drain pan under the valve 3 Install a bypass pipe and gate valve...

Страница 8: ...ully open position to the piping Step 1 in Fig 6 3 Remove the screws connecting the yoke and the valve body Step 2 in Fig 6 4 Change the direction of the yoke to the desired direction The actuator can...

Страница 9: ...ing of 4 20 mA DC input and 2 10 V DC input refer to Figs 12 to 14 and make sure the polarity of power supply and 2 10 V DC output Incorrect wiring may result in PCB printed circuit board burnout To p...

Страница 10: ...cted inside of the actuator Figure 13 Wiring terminal diagram Model VY514XJ00XX 2 10 V DC input with 2 10 V DC output type Note The terminals 2 5 and 7 are connected inside of the actuator Model VY511...

Страница 11: ...esistance input B R T1 T2 Neostat Model TY900XZ Transformer Power supply W B R Connection with Model R35TC0 Model R36TC0 Power supply Model R35TC0 Model R36TC0 Model VY513XJ 4 20 mA DC input with 2 10...

Страница 12: ...nnection of auxiliary switches OP1 OP2 OP3 OP4 OP5 OP6 Part No 83161792 001 Terminal block Auxiliary switch 1 Adjustable between 0 to 50 positions Auxiliary switch 2 Adjustable between 50 to 100 posit...

Страница 13: ...e Misaligned piping Tighten the flange bolts Replace the gasket Redo piping Fluid leaks from the gland part Loosened gland packing Tighten the gland nut Fluid leaks from the bonnet Loosened bolts Tigh...