10
VL rotary loose connector type
VK rotary lock connector type
The adaptor of level difference
connector for rotary type
Terminal cover set
Dial cover set
MTW straight connector type (double ring joint)
MK rotary lock connector type
ML rotary loose connector type
MT straight connector type
Filter set
VT straight connector type
Product code KGA65VT
Product code KGA65VRL
Product code KGA65VRK
Product code KGA65ADPA
Product code KGA65MT
Product code KGA65MRL
This connector can be rotated freely
and fi xed at any position.
This connector can be rotated freely
and fi xed at any position.
Product code TCA-65
Product code KGA65MTW-S
Product code AFS65
Two sets of fi lter, Two sets of packing
Product code TCLAMPA-65
This cover avoids trouble that
someone set dial carelessly.
For stainless tube made from stainless steel
This connector can be rotated freely
after piping.
4. About measured gas and contact failure
a) Corrosive gas
If the gas to be measured contains corrosive gases (nitric acid, hydrogen sulfide, sulfurous acid,
ammonia, chlorine, and so on), they may cause electrical contact failure or corrosion of internal
mechanism, which leads to malfunction of the switch. Do not use the switch for the gases containing
high humid air because in such gases, the arc generated by opening/ closing the contact produces nitric
acid, and it may also cause electrical contact failure or malfunction of switches.
b) Silicone gas
If the gas to be measured contains silicon produced from silicon (contained in oil, grease, filling agent,
and so on), the gas produced by arc, generates by opening/ closing the contact, accumulates on the
contact surface and causes contact failure. Take corrective measures such as the removal of the gas
source or arc suppression.
c) Dust and organic gas
The micro switch used in a Manostar switch is installed in the positive pressure measurement chamber.
The gas to be measured can easily flows into the chamber, thus, the composition of the gas largely
affects the formation of the film. In addition, the dust contained in the gas to be measured can adhere to
the contact surface and be changed into carbide caused the contact failure by the arc generated when
the contact is opened or closed. Therefore, pay attention to the measurement environment as well.
(Even with gold alloy contact, be careful about the dust.)
!
Caution
As the opening/ closing frequency of the contact increases, wear dust from the contact
increases. This wear dust accumulates between the contacts to increase the contact resistance
and causes the malfunction in the load circuit.
In particular, the surrounding where there exists continuous vibration and impact will be most
likely to cause contact failure due to worn powder.