3. Protection of contact of switch

・ Contact protection circuit is used to extend the service life of contact. It reduces generation of noise at 

the time of switching on and off. It also minimizes carbide and nitric acid gas generated by arc. Use this 
circuit correctly, otherwise it will cause reverse effect, making the matter worse.

・ In  case  of  using  contact  protection  circuit,  pay  attention  the  operating  time  is  possibility  of  delaying  a 

little. The following are typical examples of contact protection circuit.

a) Typical example of protective circuit

Example of circuit

Power supply

Special remarks for application and selection

DC

AC

Varistor
method

This  method  is  intended  not  to  apply  voltage  beyond 
limit of varistor to inbetween contacts. It delays a little 
time to return inductive load such as relay.
Select  the  most  conformed  rated  model  in  terms  of 
power  supply  voltage  and  load  capacity  in  selected 
article by varistor maker.

C・R
method

It  delays  a  little  time  to  activate  or  return  inductive 
load such as relay.
As for CR value, to contact current and contact voltage, 
the estimate value is C : 0.5 μ F / A, R : 1.0 Ω / V.
However,  it  differs  according  to  the  characteristics 
of  load,  therefore,  be  sure  to  confirm  to  select  by 
experiment.

Diode
method

×

This  method  is  intended  to  consume  counter 
electromotive  force  of  inductive  load  by  diode 
and  avoid  to  apply  high  voltage  to  inbetween  the 
contacts.
This method makes the return time of inductive load 
slower.Choose  the  diode  rated  current  is  more  than 
load current and counter withstand voltage more than 
10 times of power supply voltage.

Diode +
Zener diode
method

×

Diode method proves to be effective when the return 
time takes too long for inductive load such as relay. 
When  you  choose  zener  voltage  of  zener  diode, 
choose base on power supply voltage. Be careful with 
limitations  having  this  method.  Because  load  is  too 
big, larger capacity zener diode is needed for reverse 
surge power.

P.S. : Power supply,  I.L. : Inductive load

b) Example of wrong protection circuit

Condenser method

This  is  very  effective  to  remove  arc  at  the  time  of 
off-contact,  but  this  is  likely  to  run  charged  current 
to  condenser  leading  to  contact  sticking  and  short 
service life at the time on-contact.

This is very effective to remove arc at the time of off-
contact, but this is likely to run short circuit current 
accumulated  in  the  condenser  leading  to  contact 
sticking on contacting.
This  is  likely  to  short  service  life  at  the  time  on-
contact.

P.S. : Power supply,  I.L. : Inductive load

If the load is larger than the specifi ed contact capacity, use a secondary relay. In general, the load voltage and 
the corrent is too less to the life of contact is longer. However, this does not expect for a low electirical load. 
Manostar switches cannot directly shut off the circuit of 250 V AC or more.

ᵧᵌᵪᵌ

ᵮᵌᵱᵌ

ᵧᵌᵪᵌ

ᵮᵌᵱᵌ

ᵧᵌᵪᵌ

ᵮᵌᵱᵌ

ᵧᵌᵪᵌ

ᵮᵌᵱᵌ

ᵮᵌᵱᵌ

ᵧᵌᵪᵌ

ᵧᵌᵪᵌ

ᵮᵌᵱᵌ

Содержание MS65

Страница 1: ... U C T I O N M A N U A L 653 0031 1 2 3 Nishi shiriike cho Nagata ku Kobe Japan TEL 078 631 6000 FAX 078 631 6020 READ THE INSTRUCTION MANUAL MANOSTAR SWITCH MS65 MS65F WITH AIR FILTER TR MS65 E09 RoHS Compliant ...

Страница 2: ...Caution of piping 6 7 Installation position 6 Ⅳ SETTING OF PRESSURE 1 Switch contact configuration 7 2 Setting of upper limit lower limit 7 3 Reset time 8 Ⅴ ABOUT BUILT IN MICRO SWITCH 1 Material of contact 8 2 Contact material and applicable mecanism for low voltage and low current circuit 8 3 Protection of contact of switch 9 4 About measured gas and contact failure 10 Ⅵ ACCESSORIES 1 Accessory f...

Страница 3: ... instrument The instrument is measurable for air and non corrosive gas only The machine is exclusive use of dry air 90 RH or less Using measuring the water or oil it may be damaged and causes the accident Avoid using where the instrument is subject to many vibration and impact Using the instrument where intensified vibration and impact may be damaged the instrument It is expected that gas leaks of ...

Страница 4: ... Pa 1 2E 0 2 1 2 0 030 kPa 0 120 kPa 3E 0 5 3 0 080 kPa 0 400 kPa 6E 1 6 0 15 kPa 0 60 kPa Silicone rubber 12E 2 12 0 30 kPa 1 20 kPa 30E 5 30 0 75 kPa 4 00 kPa Out of standard 㹋㹑㸴㸳 㹄 㹆 㹔㹊 㸱㸮㸮 㹂 㸫㹉 㸫㹉 㹂 䠬䠽 㹃 䡇䠬䠽 㹆 㹊 㹔 㹋 㹋㹊 㹔㹊 㻲㼛㼞㻌㼓㼑㼚㼑㼞㼍㼘㻌㼑㼘㼑㼏㼠㼞㼕㼏㼍㼘㻌㼘㼛㼍㼐 㻲㼛㼞㻌㼘㼛㼣㻌㼑㼘㼑㼏㼠㼞㼕㼏㼍㼘㻌㼘㼛㼍㼐 㼂㼀㻌㼟㼠㼞㼍㼕㼓㼔㼠㻌㼠㼥㼜㼑㻌 㼂䠨㻌㼞㼛㼠㼍㼞㼥㻌㼘㼛㼛㼟㼑㻌㼠㼥㼜㼑 㻹㼀㻌㼠㼟㼠㼞㼍㼕㼓㼔㼠㻌㼠㼥㼜㼑 㻹䠨㻌㼞㼛㼠㼍㼞㼥㻌㼘㼛㼛㼟㼑㻌㼠㼥㼜㼑 㻲㼛㼞㻌㼡㼜㼜㼑㼞㻌㼘㼕㼙㼕㼠㻌㼟㼑㼠㼠㼕㼚㼓 㻲㼛㼞㻌㼘㼛㼣㼑㼞㻌㼘㼕㼙㼕㼠㻌㼟㼑㼠㼠...

Страница 5: ...de 10 10 to 50 Hz Acceleration 39 m s2 each two hours on triaxial directions 100 m s2 each six times on triaxial direction Between each terminal and case 20 MΩ or more 500 V DC megger Between each terminal and case 1500 V AC 50 60 Hz for one minute Phenol resin and aluminum die cast 1 Vinyl plastic or rubber tube I D 6 Piping applicable model attached with connector for vinyl or plastic tube 2 Met...

Страница 6: ...ectrical load type The general electrical load type is decreased contact reliability refer to p 8 The withstanding pressure of the pressure receiving element means The max pressure under which the diaphragm withstands distortion or breakage withstand single pressure The single pressure acting on either H or L side The withstanding pressure of the instrument body means The max pressure under which ...

Страница 7: ...de piping connector blue or L The high pressure port red or H should be opened to atmosphere but do not remove the piping connector c Measurement of differential pressure Connect the tube from the high pressure piping connector to the high pressure port red or H and from the low pressure piping connector to the low pressure port blue or L 4 Connectors and piping material a Connectors for vinyl or ...

Страница 8: ...nnect it with the pressure receiving instrument through a metal tube which is long enough to cool down the high temperature gas d Errors caused by long distance piping The speed of response is delayed when the product is used for remote monitoring In such application the I D of the connection tube should be as large as possible The time constant is almost inversely proportional to the inner cross ...

Страница 9: ...e Be careful about the difference between the upper and lower limit setting switched and also understand the relation between the pressure increase decrease and the contact composition before designing the operational sequence Depending on the purpose of use choose the instrument either upper limit setting type or lower limit setting type Difference of contact movement between upper limit setting ...

Страница 10: ... small rivet contact point 2 Contact material and applicable mecanism for low voltage and low current circuit The schematic diagram in the right explains the proper range of load voltage and current for which silver or gold alloy contact is generally used when the contact is used for opening or closing the low voltage and low current circuit with a micro switch When referring to the diagram keep t...

Страница 11: ...iode and avoid to apply high voltage to inbetween the contacts This method makes the return time of inductive load slower Choose the diode rated current is more than load current and counter withstand voltage more than 10 times of power supply voltage Diode Zener diode method Diode method proves to be effective when the return time takes too long for inductive load such as relay When you choose ze...

Страница 12: ...ic acid and it may also cause electrical contact failure or malfunction of switches b Silicone gas If the gas to be measured contains silicon produced from silicon contained in oil grease filling agent and so on the gas produced by arc generates by opening closing the contact accumulates on the contact surface and causes contact failure Take corrective measures such as the removal of the gas sourc...

Страница 13: ...again to fix Replacement of air filter In case of using model with air filter MS65F depending on amount of work conduct disassembly and clean out once in 2 years periodically and replace filters and packings with new ones Filters are constructed as shown in Fig 1 How to change 1 Loosen and take out four assembly screws a from the instrument body and disassemble filter unit 2 Remove the used filters and ...

Страница 14: ...G VT6 S Product code FG MT6 S T joint For vinyl or plastic tube Product code TVT6 4 6 For branching different I D 6 and 4 Product code TVT6 6 6 For branching the same I D 6 and 6 Product code Applicable range max value For vinyl or plastic tube For metal tube Pa kPa RS VT6 02 RS MT6 02 200 Pa or less RS VT6 03 RS MT6 03 300 500 1000 Pa RS VT6 04 RS MT6 04 2 3 5 10 kPa RS VT6 06 RS MT6 06 20 kPa or...

Страница 15: ...talog specifications or manual Handling or usage of the product other than as described in our product catalog specifications or manual 2 Breakdown due to a reason other than a fault within our product 3 Any product that has been modified or repaired by a party other than us 4 Any breakdown due to a reason that was not foreseeable based on scientific and technical standards applied at the time of ship...

Отзывы: