Auto setup for appropriate surround effects (IntelliBeam)
4
Press the ENTER key to start the AUTO SETUP
procedure and then leave the room within 10
seconds.
If the AUTO SETUP procedure is complete, this unit rings
the chimes.
• The AUTO SETUP procedure takes about 3 minutes.
• To cancel the AUTO SETUP procedure after it is started, or if you do not
want to apply the results, press the RETURN (
) key.
• If an error occurs, an error buzzer sounds and an error message is
displayed. For details on error messages, see page 34 in the Owner’s
Manual.
5
Press the ENTER key.
The measurement results are applied and saved in the unit.
• You can save several measurement results by pressing
the SYSTEM MEMORY 1, 2, or 3 key.
When the SYSTEM MEMORY 1 key is pressed, “M1
Saving” is displayed, and settings are saved.
• If ambient noise is picked up after measurement begins,
an error message is displayed in the “AUTO SETUP
COMPLETE” screen prompting you to begin
measurement again. Press the ENTER key to exit the
error message screen, and begin measurement again.
• See page 45 in the Owner’s Manual for more information on the system
memory function.
6
Remove the IntelliBeam microphone.
The “AUTO SETUP COMPLETE” screen closes.
The IntelliBeam microphone is sensitive to heat, so should
not be placed anywhere where it could be exposed to direct
sunlight or high temperatures (such as on top of AV
equipment).
S H O W R E S U L T
M E A S U R E M E N T C O M P L E T E .
E N V I R O N M E N T C H E C K : S u c c e s s
F R O N T : B e a m
S U R R O U N D : B e a m
S U B W O O F E R : W i r e d
[ E N T E R ] : S a v e s e t - u p .
[ R E T U R N ] : D o n o t s a v e s e t - u p .
A U T O S E T U P S T A R T
W i l l b e g i n i n 1 0 s e c .
P l e a s e l e a v e t h e r o o m .
- - - - - - - - - -
[ R E T U R N ] : C a n c e l
The screen changes
automatically as measurement
progresses.
A U T O S E T U P C O M P L E T E
P l e a s e r e m o v e t h e M I C
f r o m S o u n d P r o j e c t o r
a n d t h e l i s t e n i n g p o s i t i o n .
P r e s s [ S Y S T E M M E M O R Y ] k e y
t o s a v e s e t - u p i n t h e m e m o r y .
INTELLIBEAM MIC
INTELLIBEAM MIC
1 2 3 4
RETURN ( )
S
Y
S
TEM
MEMORY
ENTER