4-2
E
1. Put the watercraft on land in a horizontal
position.
2. Open the flushing hose connector
cap
1
, and then insert the garden hose
adapter
2
into the flushing hose con-
nector
3
and turn it until it is securely
connected.
3. Connect the garden hose adapter to a
water tap using a hose.
4. Start the engine, and then immediately
turn the water supply on until water flows
out continually from the cooling water
pilot outlet.
5. Run the engine at idling speed for about
3 minutes watching the engine condition.
If the engine stops while flushing, turn
the water supply off immediately and
repeat the above steps.
6. Turn the water supply off, and then force
the remaining water out from the cooling
passages by running the engine at
4,000 r/min or less within 10 to
15 seconds.
7. Stop the engine.
8. Remove the garden hose adapter and
secure the cap.