3 - 8
INSP
ADJ
RADIATOR CAP INSPECTION/
RADIATOR CAP OPENING PRESSURE INSPECTION
12. Install:
●
Coolant reservoir cap
13. Start the engine and let it warm up for
several minutes.
14. Turn off the engine and inspect the cool-
ant level.
Refer to “COOLANT LEVEL INSPEC-
TION” section.
NOTE:
Before checking the coolant level wait a few
minutes until the coolant settles.
EC355000
RADIATOR CAP INSPECTION
1. Inspect:
●
Seal (radiator cap)
1
●
Valve and valve seat
2
Crack/damage
→
Replace.
Exist fur deposits
3
→
Clean or
replace.
EC356001
RADIATOR CAP OPENING PRESSURE
INSPECTION
1. Attach:
●
Radiator cap tester
1
and adapter
2
NOTE:
Apply water on the radiator cap seal.
3
Radiator cap
2. Apply the specified pressure.
Radiator cap tester:
YU-24460-01/90890-01325
Adapter:
YU-33984/90890-01352
Radiator cap opening pressure:
110 kPa (1.1 kg/cm
2
, 15.6 psi)