2
Installation and wiring
2-15
6. Connecting the regenerative unit TS-X TS-P
The regenerative unit absorbs regenerative current produced during motor speed reduction and radiates it
as heat. A regenerative unit is required when operating certain robot models specified by YAMAHA or when
handling large-inertia loads. Use the YAMAHA-specified dedicated cable to connect a regenerative unit to
the controller.
6.1 Connecting the RGT
TS-X
TS-P
The following explains how to connect the RGT.
c
CAutIoN
• The power must be off when connecting the regenerative unit.
• Insert the cable plug into the connector until a clicking sound is heard (fully inserted).
• Install the regenerative unit in a well ventilated location with ample peripheral space (20mm or more).
Controller
RGT
Dedicated
cable
Ground terminal
20mm
or more
Connecting the RGT
23208-M1-00
Ground terminal
n
The controller must be grounded to prevent electrical shocks in case of electrical leakage, and to prevent equipment
malfunctions due to electrical noise.
A Class D or higher grounding (grounding resistance of 100
Ω
or less) is required.
w
WARNING
BE SuRE thAt GRouND IS SECuREly CoNNECtED.
Tighten the ground terminal screw to the torque shown below.
Recommended Tightening Torque
0.75N·m
Содержание TS-P
Страница 2: ......
Страница 12: ......
Страница 14: ......
Страница 28: ......
Страница 70: ......
Страница 72: ......
Страница 92: ......
Страница 164: ......
Страница 172: ......
Страница 174: ......
Страница 230: ......
Страница 232: ......
Страница 254: ......
Страница 274: ......
Страница 276: ......
Страница 285: ......