56
STAGEPAS 600i
2-13. Frequency Response
(1) Set the level control (CH1, MASTER) to the
maximum position, and the MIC/LINE switch to the
MIC position.
The signal of -62 dBu is input to CH1 (XLR), and the
output voltage is measured.
Measurements are recorded.
SPEAKERS OUT (L/R)
: (A1)
(2) Set the level control (CH1, MASTER) to the
maximum position, and the MIC/LINE switch to the
MIC position.
The sine wave of 40 Hz, -62 dBu is input to CH1
(XLR), and the output voltage is measured.
SPEAKERS OUT (L/R)
Con
fi
rm that the range of -1±2 dB based on A1.
(3) Set the level control (CH1, MASTER) to the
maximum position, and the MIC/LINE switch to the
MIC position.
The sine wave of 20 kHz, -62 dBu is input to CH1
(XLR), and the output voltage is measured.
SPEAKERS OUT (L/R)
Con
fi
rm that the range of -1±2 dB based on A1.
* Measure each output individually.
Table 1
(表 1)
[dBu]
No.
Measurement condition
(測定条件)
Criteria
(判断基準)
INPUT
(入力)
OUTPUT
(出力)
Terminal
(端子)
Level
(レベル)
Switch *1
(スイッチ *1)
Terminal
(端子)
Level control
(LEVEL コントロール)
OUTPUT LEVEL
(出力 LEVEL)
(1) CH1 (XLR)(Balanced)
-56
MIC/LINE: MIC
MONITOR L
MONITOR: Max
+4.5±2
q
MONITOR R
+4.5±2
w
LEVEL difference
q
and
w
within 2dB
SUBWOOFER
MASTER LEVEL: Max
+1±2
(2) CH2 (XLR)(Balanced)
-56
MIC/LINE:MIC
MONITOR L
MONITOR: Max
+4.5±2
(3) CH3 (XLR)(Balanced)
-56
MIC/LINE:MIC
MONITOR L
+4.5±2
MONITOR R
+4.5±2
(4) CH4 (XLR)(Balanced)
-56
MIC/LINE:MIC
MONITOR L
+4.5±2
MONITOR R
+4.5±2
(5) CH5 (PHONE)(Unbalanced)
-24
–
MONITOR L
+4±2
(6) CH6 (PHONE)(Unbalanced)
-24
–
MONITOR R
+4±2
(7) CH7 (PHONE)(Unbalanced)
-24
–
MONITOR L
+4±2
–
MONITOR L(MONO) *2
-2±2
ST/MONO: MONO MONITOR L(MONO) *2
+4±2
CH7 (RCA PIN)(Unbalanced) *3
-24
–
MONITOR L
+4±2
(8) CH8 (PHONE)(Unbalanced)
-24
–
MONITOR R
+4±2
CH8 (RCA PIN)(Unbalanced) *3
-24
–
MONITOR R
+4±2
(9) CH9 (PHONE)(Unbalanced) *4
-24
–
MONITOR L
+4±2
CH9 (MINI JK L)(Unbalanced)
-24
–
MONITOR L
+4±2
(10) CH10 (PHONE)(Unbalanced) *4
-24
–
MONITOR R
+4±2
CH10 (MINI JK R)(Unbalanced)
-24
–
MONITOR R
+4±2
*1 Operate the input channel elements which the signal is applied.
(信号入力するチャンネルの操作子のみ操作してください。)
*2 When measuring the MONITOR L/MONO, disconnect the plug of the MONITOR R.
(
MONITOR L
(
MONO
)測定時は
MONITOR R
のプラグを抜いてください。)
*3 When measuring the RCA PIN input, disconnect the phone plug. (Phone input is preferred.)
(
RCA PIN
入力測定時は、ホーンプラグを抜いてください。(ホーン入力優先))
*4 When measuring the PHONE input, disconnect the MINI PHONE plug. (MINI PHONE input is priority.)
(ホーン入力測定時は、ミニホーンプラグを抜いてください。(ミニホーンプラグ優先))
2-13. 周波数特性
(1) LEVEL コントロール(CH1、MASTER)を最大、
MIC/LINE スイッチを MIC に設定します。
CH1(XLR)に -62 dBu の信号を入力し、出力
電圧を測定します。
測定値を記録します。
SPEAKERS OUT (L/R) : (A1)
(2) LEVEL コントロール(CH1、MASTER)を最大、
MIC/LINE スイッチを MIC に設定します。
CH1(XLR)に 40 Hz, -62 dBu の正弦波を入力し、
出力電圧を測定します。
SPEAKERS OUT (L/R)
A1 を基準に -1 ± 2 dB の範囲内であること
を確認します。
(3) LEVEL コントロール(CH1、MASTER)を最大、
MIC/LINE スイッチを MIC に設定します。
CH1(XLR) に 20kHz, -62dBu の正弦波を入力し、
出力電圧を測定します。
SPEAKERS OUT (L/R)
A1 を基準に -1 ± 2 dB の範囲内であること
を確認します。
※各出力を個別に測定してください。